 New GC Columns for Higher Stability and Sensitivity Introduced
 
  September 14 2006
 
  Chromatography and Mass Spectrometry
 
ORLANDO, Florida (March 3, 2005) – Thermo Electron Corporation announces two new additions to its recently launched range of TRACE™ GC columns, the TRACE TR-WaxMS and the TRACE TR-1701. These new columns are characterized by a high temperature range and low bleed levels, leading to higher sensitivity, less need for instrument cleaning and longer column lifetimes and they will be exhibited at the Thermo Electron booth #2917 at PITTCON 2005, Orange County Convention Center, Orlando, Florida, February 27-March 4.

Designed to offer application-focused solutions to customers in the petrochemical, food and beverage and environmental industries, Thermo’s enhanced GC range of TRACE GC columns, syringes and consumables including injection port liners, ferrules and septa, is designed to complement Thermo’s innovative range of Finnigan™ GC and GC/MS systems.

High polarity GC columns typically have lower temperature ranges than low polarity dimensionally equivalent ones. This severely limits the use of mass spectrometry for detection as well as the range of compounds that can be analyzed. Thermo’s new TRACE TR-WaxMS column features high stability phase bonding that results in low bleed and an extended Maximum Allowable Operating Temperature of 300°C. This stability also results into a strong resistance to water, which combined with the temperature range makes the TR-WaxMS one of the most versatile, sensitive, stable and long-lasting WAX phase GC columns on the market. This column is ideal for alcohol, ester and aldehyde analysis.

The new TRACE TR-1701 capillary GC column, with 14% cyanopropylphenyl polysiloxane offering a different elution order, is an important addition for those involved in the analysis and detection of pesticides and related compounds. In combination with other columns such as the TR-5 or TR-50MS, the more mid-polarity TR-1701 phase can be used to confirm and identify the pesticides detected.

For more information about Thermo’s new TR-WaxMS and TRACE TR-1701 GC columns, please visit Thermo at booth #2917, at PITTCON 2005 in Orlando. Alternatively, please call +1 800-532-4752, e-mail analyze@thermo.com or visit www.thermo.com/columns.

About Chromatography and Mass Spectrometry
A leader in ion trap, hybrid and magnetic sector mass spectrometers, liquid and gas chromatographs and hyphenated multi-instrument combinations of these products, Thermo Electron’s integrated solutions include state-of-the-art instrument systems, advanced software and HPLC column technology with a wide range of innovative phases and hardware designs – tailored to meet the rigorous demands of lab professionals in applications such as proteomics, drug discovery, environmental analysis and analytical quantification. For more information, visit www.thermo.com/columns .

About Thermo Electron Corporation
Thermo Electron Corporation is the world leader in analytical instruments. Our instrument solutions enable our customers to make the world a healthier, cleaner and safer place. Thermo's Life and Laboratory Sciences segment provides analytical instruments, scientific equipment, services and software solutions for life science, drug discovery, clinical, environmental and industrial laboratories. Thermo's Measurement and Control segment is dedicated to providing analytical instruments used in a variety of manufacturing processes and in-the-field applications, including those associated with safety and homeland security. Based near Boston, Massachusetts, Thermo has revenues of more than $2 billion, and employs approximately 10,000 people in 30 countries.