The Thermo Scientific Orion 1803 is designed to take a high pressure steam sample (e.g. the process steam used in power plants, paper mills, oil refineries etc.) and reduce the temperature and pressure down to the levels required by our online analyzers. Process steam is used in many industries; it is the analysis of this steam that has made Orion online analyzers so important in the power, paper, petrochemical and other industries.
Product Detail
Handles pressures of up to 20,897 K Pa (3030 psi). The usual average pressure of process steam is approximately 6,896 K Pa (1000 psi).
Able to reduce the temperature of the sample from 538°C (1000°F) to under 38°C (100°F).
Purely mechanical, requiring no electrical hook up, so it can be used in multiple countries regardless of the voltage requirements. It can also be used in hazardous locations (e.g. petrochem) without any danger of explosion.
Has a mechanical temperature shut off valve which will trip if the temperature exceeds 40°C (104°F) -- If a cooler fails or the cooling water becomes too hot, the valve diverts the hot sample away from the online monitor, avoiding costly damage.