Product Browse Products >>... >> Contamination Monitoring Systems >> Gamma Portal Monitors
SPM-906

  SPM-906



The SPM-906 enables fast, all-over monitoring with exceptional sensitivity. This complete, stand-alone system was designed utilizing sturdy, durable construction. The SPM-906 takes the complication out of personnel radiation monitoring with easy routines for set up and calibration.

   Product Detail


This monitor is designed to automatically perform consistent, thorough scanning. Designed primarily as a contamination monitor, the SPM-906 will detect less than 100nCi of mixed fission/activation products on a walk-pause-walk basis.

Set up is accomplished using the hand-held terminal, or a computer with a Windows 95/NT communications program. Both the terminal and the program are included with the system.

When an alarm occurs, the system will sound an audio alarm, and indicate which detector(s) alarmed to help locate the source of contamination. When the system is idle, the background is continuously updated. In the event of a power outage, an internal battery provides eight hours of continuous operation.

SENSITIVITY: SNM applications - for 235U and 239Pu. For Health Physics, detects less than 100 nanocuries (3,700 Bq) of mixed activation products in a nominal 20 µR/hr background (0.20 µSv).

DETECTORS: Two, 12" x 38" x 1.5" (30 x 97 x 3.8 cm) organic plastic scintillator detectors per pillar. One, 10" x 12" x 1.5? (25 x 30 x 3.8 cm) organic plastic scintillator detector at both the head and foot. Total volume of scintillator per system: 3,096 in3 (50.8 liters).

FALSE ALARM RATES: Typically less than 1 in 1,000 passages. NOTE: Sensitivity and False Alarm Rate are interdependent and must be optimized for different background levels.

 
Purchase Details
SKU : SPM-906 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Power Requirements :External 90 - 250 Vac, 50 VA line power; stand-by power 12 Vdc sealed lead acid battery
Passage Time :Variable from walk-through to 10 seconds; typically 3 seconds on a walk-pause-walk basis.
Serviceability :Self-checking routines and easily performed tests simplify board level troubleshooting. Most electronic assemblies are readily accessed by removing the panels in the center of the vertical pillars.
Dimensions :88" h x 40" w x 18? d (224 x 100 x 46 cm), pillar spacing is fixed at 24" (61 cm)
Weight :1200 lbs (544 kg) complete monitor, 1500 lbs (682 kg) packed. Lead Shielding is 0.75? (1.9 cm)
Environmental :32° to 122° F (0° to 50° C) Designed for use in an indoor area.