Zero Air Supply Calibrator, Model 1160

  Zero Air Supply Calibrator, Model 1160



A modular tool for laboratories calibration services where pollutant free air is required.

   Product Detail


The Model 1160 is a source of ultra high purity zero air for analytical and process instrument needs.  This modular unit can be configured for the removal of a variety of pollutant gases.  Up to 20 liters per minute of clean dry air can be supplied at pressures up to 60 psgi via a self-contained compressor.  This devise can be used for the calibration of environmental instrumentation or as an air supply in analytical laboratories.

The air supply can be configured to operate with or without an internal compressor.  If dry air is required, two types of dryers are available; a membrane dryer which will supply the air at a nominal dew point of +5°C or a regenerative of heatless dryer with an output of -40°C.  When the removal of CO or Hydrocarbons is desired a catalytical converter is available and for scrubbing of most other pollutants chemical scrubbers can be installed.  A choice of one, two or three scrubber cartridges can be chosen.  These scrubber cartridges can be filled with a variety of materials to suit the application, including; Charcoal, Silica Gel or other absorbent, PurefilTM, Soda Lime, Mole Sieve, and more.

Key Features / Benefits:

  • The ability to select one, two, or three scrubbers with customer option of scrubber materials
  • A choice of dryer types or no dryer at all
  • With or without CO and Hydrocarbon reactor
  • Temperature alarms for system applications
  • 20 liters per minute supply of air
 
Related Products
 Product# Product Name Image  
  111   Zero Air Supply, Model 111
  Select  
 
Purchase Details
SKU : 1160 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Pollutant Concentration Data - SO2 :< 0.1 ppb
Pollutant Concentration Data - NO :< 0.1 ppb
Pollutant Concentration Data - NO2 :< 0.1 ppb
Pollutant Concentration Data - O3 :< 0.4 ppb
Pollutant Concentration Data - H2S :< 0.1 ppb
Pollutant Concentration Data - NH3 :< 0.1 ppb
Pollutant Concentration Data - CO (optional) :< 0.02 ppm
Pollutant Concentration Data - Hydrocarbons :< 0.005 ppm
Flow Rate :1-20 lpm
Pressure :10-60 psig
Dew Point :Membrane Dryer: -10°C; Heatless Dryer: -40°C
Operating Temperature :-10 to 40°C
Power Supply :100 to 240V, 50 to 60 Hz (+/- 10%); Instrument: 30 watts; Pump: 100 watts
Size :19" (W) x 12.4" (H) x 15.75" (D); 483mm (W) x 315mm (H) x 400mm (D)
Weight :25kg (approximately)