Revco Ultima II Series Cryogenic Freezers

  Revco Ultima II Series Cryogenic Freezers



Developed for the most critical material storage, Ultima II represents the finest, most enhanced cryogenic freezer anywhere.

   Product Detail



Cryogenic Temperatures Without Liquid Nitrogen

  • REVCO Ultima II cryogenic freezers are designed for long-term storage of biologicals at uniform temperatures of -140°C and -150°C, safely below
    the -130°C glass transition temperature of water
  • Cell viability is improved because biologically relevant, thermally driven reactions are not known to occur

Safer, More Convenient Than LN2

  • REVCO cryogenic freezers include all features, control and performance attributes of the Ultima II Series freezers, plus many important advantages not available when using LN2
  • Stable cryogenic temperature of -140°C and -150°C without LN2 as a cooling medium
  • Patented, single compressor, orbital refrigeration system
  • Top-to-bottom temperature uniformity dramatically improved when compared to LN2 vapor
  • Lower operating costs than LN2 freezers of similar capacity
  • 100% of interior space is usable, with stored samples maintained below critical temperature
  • Ample interior volume with capacity of up to 21,600 samples in Model ULT-10140 and up to 14,400 samples in Model ULT-7150 (2 ml vials in boxes)
  • Uses standard REVCO inventory racks and fiberboard boxes

High-capacity, Air-cooled Refrigeration System

  • Exclusive mixed refrigerant autocascade with a single, orbital refrigeration compressor
  • CFC-free refrigerants
  • Downfeed evaporator for most efficient refrigerant flow
  • High-capacity air-cooled condenser with dual condenser fans, aerodynamically shaped fan blades
  • Washable condenser filter keeps fins free of dust to maintain peak cooling efficiency; no tools required for removal

Dependable, Exclusive Microprocessor Control System

  • IntrLogic™ system with touchpad data entry and digital display of all functions
  • Setpoint security system with key-operated switch for main power and alarm
  • Independent operating temperature and high/low limit alarm functions with factory-set defaults for quick start-up, all setpoints adjustable in 1°C increments

Electrical System Protects Against Surges

  • Automatic voltage boost compensates for low voltage and brownout conditions
  • On-board power monitoring with digital readout of incoming line voltage
  • Built-in surge suppressor minimizes effect of voltage spikes from incoming electrical service

Sophisticated Alarm System Gives You Peace-of-Mind

  • A.I.M. (Automatic Incident Monitor) identifies any temperature deviation beyond alarm setpoints, with rapid flash for current event, slow flash if event was self corrected; A.I.M. archives most deviated temperature
  • Adjustable safety alarm with automatic, continuous charge battery backup provides full function in case of power failure
  • Power failure or temperature deviation triggers audible and visual warning
  • Digital batter indicator displays battery capacity; flashing low battery indicator advises when to replace battery
  • Touchpad alarm test function physically warms internal probe to simulate alarm condition
  • RS-232 data port with system software package
  • Exterior alarm contacts for connection to remote monitoring system

Convenient Monitoring System Reminds You When to Take Action

  • Lifeguard compressor protection monitors performance and automatically adjusts to internal and external conditions, extending compressor life
  • Extreme ambient alert warns if room temperature may affect performance
  • Voltage boost indicator advises of low source voltage below safe parameters and indicates voltage boost system is activated
  • Surge suppressor indicator advises to check intercept fuse
  • Clean filter indicator light advises when to remove and wash condenser filter

Low-Profile Chest Cabinet Construction for Easier Access to Inventory

  • Heavy duty counterbalanced lid with integrated keyed lid lock for security
  • Double seal lid gaskets to minimize frost buildup
  • Independent sub-lids provide additional protection
  • Minimum 5" (127 mm) foamed-in-place urethane insulation, closed-cell, CFC-free, to protect product against high ambient conditions
  • Heavy-gauge steel cabinet with high-impact powder paint finish
  • Rounded interior corners for easy cleaning
  • Access port, 1" (25.4 mm) diameter, with cap
  • Recessed heavy duty swivel casters
 Revco Ultima II Series Cryogenic Freezers
 Product# Price  Volume
Liters (cu.ft)
 Voltage  
         
 ULT-10140-9D      -    292 (10.3) 208/230V 60Hz 1Ø   SELECT  
 ULT-10140-9E      -    292 (10.3) 208/230V 60Hz 3Ø   SELECT  
 ULT-10140-9M      -    292 (10.3) 380V 50Hz 3Ø   SELECT  
 ULT-10140-9R      -    292 (10.3) 200V 50Hz 3Ø   SELECT  
 ULT-10140-9V      -    292 (10.3) 230V 50Hz 1Ø   SELECT  
 ULT-10140-9W      -    292 (10.3) 230V 50Hz 1Ø   SELECT  
 ULT-7150-9D      -    193 (5.8) 208/230V 60Hz 1Ø   SELECT  
 ULT-7150-9E      -    193 (5.8) 208/230V 60Hz 1Ø   SELECT  
 ULT-7150-9M      -    193 (5.8) 380V 50Hz 3Ø   SELECT  
 ULT-7150-9R      -    193 (5.8) 200V 50Hz 3Ø   SELECT  
 ULT-7150-9V      -    193 (5.8) 230V 50Hz 1Ø   SELECT  
 ULT-7150-9W      -    193 (5.8) 230V 50Hz 1Ø   SELECT  
Purchase Details
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Services
  • 2009 Product Service Training - Controlled Environment
  • Search Our eService Knowledge Base
  • Validation for Laboratory Equipment
  • Specifications:
    Temperature :
    ULT-7150-9 :-150ºC
    ULT-10140-9 :-140ºC
    Plugs :E, M, R, V and W require a hardwire connection by customer