Orion 1817LL Low-Level Chloride Analyzer

  Orion 1817LL Low-Level Chloride Analyzer



Used to monitor boiler water and boiler blow down, the Orion 1817LL is an indicator that could detect costly condenser leaks.  This system includes a new reference electrode, a double junction ceramic frit electrode designed to provide outstanding long term performance; and a chloride sensor known for its superior accuracy at low levels. 


   Product Detail


The Orion 1817LL has a limit of detection of 10±5 ppb. A refrigeration unit cools the sample down below 12 °C which enables the sensor to detect chloride at extremely low levels without additional manipulation of the sample.

  • Measures down to 5 ppb chloride
  • Low cost of operation
  • QC Sampling Capabilites: Validation using standards; Grab samples; Alternative to lab analyses
  • Integrated sample temperature control for lower levels of detection
  • Low maintenance
  • Ease of calibration
 Orion 1817LL Low-Level Chloride Analyzer
 Product# Price  Description  
       
 1817LL      -    Monitor with Cooler   SELECT  
 1817LL100      -    Monitor with Cooler   SELECT  
 1817LL230      -    Monitor with cooler   SELECT  
 1817CAL      -    Calibrator Kit   SELECT  
Purchase Details
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Measuring Range :5ppb to 10 ppm chloride
Display :Four and one half LCD digits for concentration, slope, zero-potential, error codes and diagnostic information
Signal Output :Provides selection of 4-20 or 0-20 mAmps, isolated max. load 1000 ohms, and 0-5 or 0-10V DC, isolated min. load 1000 ohms. Mimimum range 2 decades
Accuracy/Precision :10% of reading or ± 5 ppb, whichever is greater, within ± 5°C of calibration temperature
Drift :0.1 ppm per month or 10% or reading whichever is greater
Sample Conditions :Temperature: 5-45°C Total alkalinity: less than 50 ppm CaCO3 Sulfite must not be present
Response Time :90% within 2 minutes function of flow and volume
Cooled Sample Temp :5-12°C
Sample Inlet :1/4" NPTF tube fitting
Sample Outlet :3/4" NPT-male
Calibration :Three-point and off-line calibration
Flow :40 mL/min nominal set by pressure regulator
Environment :Temperature: 5-45°C Humidity: 95% relative maximum, non-condensing protection; splash-water proof IP54
Pressure :8 psig up to 100 psig
Shipping Dimension :Monitor: 65 x 45 x 27 cm (h.w.d)
Cooler: 26 x 17 x 11 in (h.w.d)
Shipping Weight :31.4 kg / 69 lbs
Electrical Requirements :100/115/220 or 240V AC, ± 10% 50/60 Hz, 100 watts