This microprocessor-based monitor calculates the margin to Departure from Nucleate Boiling and calculates the low pressure trip setpoint, using as inputs the temperature at the reactor inlets and outlets and the neutron flux readings from the upper and lower ex-core detectors.
Product Detail
This microprocessor-based monitor calculates the margin to Departure from Nucleate Boiling (DNB) and calculates the low pressure trip setpoint, using as inputs the temperatures at the reactor inlets and outlets and the neutron flux readings from the upper and lower ex-core detectors. The monitor is an integral part of the plant's Reactor Protection System.