Genesis Toxigen Configuration - 4 Gas Monitor
The Genesis Toxigen Four Gas Monitor detects oxygen, combustible and two toxic gases: H2S, NH3, Cl2, HCN, NO, NO2, SO2 or hydride (PH3, AsH3, SiH4)
Product Detail
The Genesis personal portable four-gas toxigen monitor detects combustible, O2, and two of the following "Toxigen" gases: NH3, Cl2, HCN, NO, NO2, SO2, hydride (PH3, AsH3, SiH4).
The Genesis can be used in four configurations:
Diffusion
Built-in sample pump
Hand-aspirated pump
Extender cable
Features:
Optional internal datalogging
TWA/STEL alarms
Simple one-button calibration
Interchangeable 3-AA alkaline batteries or rechargeable NiHy
Peak, STEL and TWA readings
RF resistant
Range of Gases Detected:
Gases:
Formula:
Standard Range:
Ammonia
NH3
0 - 100 ppm in 1 ppm increments
Carbon Monoxide
CO
0 - 250 ppm in 1 ppm increments
Chlorine
Cl2
0 - 9.9 ppm in 0.1 ppm increments
Combustible
LEL
0 - 100% LEL in 1% LEL increments
Hydrogen Cyanide
HCN
0 - 30 ppm in 1 ppm increments
Hydrogen Sulfide
H2S
0 - 200 ppm in 1 ppm increments
Nitric Oxide
NO
0 - 100 ppm in 1 ppm increments
Nitrogen Dioxide
NO2
0 - 9.9 ppm in 0.1 ppm increments
Oxygen
O2
0 - 30.0% Vol in 0.1% increments
Phosphine
PH3
0 - 3.00 ppm in 0.01 ppm increments
Sulfur Dioxide
SO2
0 - 9.9 ppm in 0.1 ppm increments
Sensor Compatability Chart
CO
H2S
CL2
HCN
NH3
NO
NO2
SO2
PH3
CO
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
H2S
Yes
-
Yes
-
Yes
-
Yes
Yes
CL2
Yes
-
-
-
Yes
-
-
Yes
HCN
Yes
Yes
-
Yes
Yes
-
-
Yes
NH3
Yes
-
-
Yes
-
Yes
-
Yes
NO
Yes
Yes
Yes
Yes
-
Yes
-
Yes
NO2
Yes
-
-
-
Yes
Yes
Yes
Yes
SO2
Yes
Yes
-
-
-
-
Yes
Yes
PH3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Genesis Toxigen Configuration - 4 Gas Monitor
Purchase Details
Contact Sales
United States +1 866 282 0430
Canada +1 866 282 0430
Caribbean +1 866 282 0430
Mexico +1 866 282 0430
Argentina +1 866 282 0430
Chile +1 866 282 0430
Other Latin Amer +1 866 282 0430
Austria +31 76 579 5641
Belgium +31 76 579 5641
Denmark +31 76 579 5641
Finland +31 76 579 5641
France +31 76 579 5641
Germany +31 76 579 5641
Ireland +31 76 579 5641
Italy +31 76 579 5641
Luxembourg +31 76 579 5641
Netherlands +31 76 579 5641
Norway +31 76 579 5641
Portugal +31 76 579 5641
Russia +31 76 579 5641
Spain +31 76 579 5641
Sweden +31 76 579 5641
Switzerland +31 76 579 5641
United Kingdom +44 118 971 5109
Other Europe +31 76 579 5641
China +86 10 84193588
India +65 9296 9646
Japan +65 9296 9646
Middle East +65 9296 9646
Other Asia +65 9296 9646
South Africa +31 76 579 5641
Other Africa +31 76 579 5641
Australia +65 9296 9646
Oceania +65 9296 9646
Specifications:
Gas Type : Cl2, CO, HCN, H2S, O2, NH3, NO, NO2, PH3, SO2
Sensors : Catalytic - Combustible Gases (Electrochemical - Toxic Gases)
Sampling Method : Diffusion (Standard) / Sample-Draw (optional built-in pump) / Extender cable (optional 20 ft or 50 ft)
Power Source : 3-AA Alkaline or NiHy battery pack
Battery Life : Alkaline: 22 hours without pump or 11 hours with pump (NiHy: 16 hours without pump or 8 hours with pump)
Intrinsic Safety : UL Classified, CSA and LCIE / EEX Certified
Instrument Warranty : 2 year (materials & workmanship)