Shandon Grosslab? Senior Grossing Workstation

  Shandon Grosslab? Senior Grossing Workstation



  • Stainless steel construction.
  • Fixed-height or elevating work surfaces.
  • Hands-free or manual controls.
  • Three efficient ventilation options.  
   Product Detail


Three Ventilation System Options
  • Some models feature formaldehyde neutralizing filters and recirculated air.
  • Models that use filters and an integral blower are available for short-distance applications.
  • Other models connect to the facility exhaust system.
  • See the following page for technical information on air processing options. Superior Quality
  • Stainless steel work surfaces and panels.
  • Extruded aluminum frame is designed to distribute weight evenly, stand up to heavy use, resist corrosion, add durability and minimize unit weight.
  • Ships in two easily manageable pieces that fit through standard doorways.
  • Built tough to stand up to years of heavy work without corrosion. Programmability
  • Programmable microprocessor allows clock time to be changed or the filter replacement alarm to be reset.  


Superior Functionality
  • Models with elevating work surface or with fixed-height work surface are available.
  • Elevating units have a user-adjustable work surface from 33.5" to 45.5" (85.1 to 115.6 cm).
  • Fixed-height units have a work surface that is factory set to your specification from 33.5" to 45.5" (85.1 to 115.6 cm).
  • Deep sink with hot and cold water faucet.
  • 1/2 horsepower disposal is standard; optional 3/4 horsepower disposal is available (please check with local authorities before ordering a unit with disposal; some areas prohibit the use of disposals).
  • Hands-free or manual controls for water, disposal, and optional dictation system.
  • Abundant light directed to the work surface.
  • Vacuum breaker-protected water supply.
  • Appliances plug directly into the unit for convenient use.
  • One hospital-grade duplex ground fault circuit interrupter (GFCI) receptacle on 110-120V units.
  • Two IEC 320 receptacles on 220-240V units.
  • Facility supplied residual current device (RCD) is required for 220-240V units.
  • Two optional tape recording units available.
  • Each unit comes complete with a magnetic tool bar, integral centimeter rulers, formalin dispenser, and paper towel dispenser.
  •  Built-in table rinse washes down work surfaces quickly.


Designed for Easy Shipping and Installation
  • All units ship in two convenient pieces.
  • Both parts fit through a standard 32" (81.3 cm) doorway.
  • The two halves link firmly with easy-to-lock latches.
  • The unit connects directly to the facility’s hot and cold water supplies and drain.
  • Units are hard wired to the facility’s electrical system.


Choosing the Exhaust System to Fit Your Lab
Recirculating
For existing labs or labs without facility exhaust, it may be necessary to filter and recirculate the air. Specify a unit with integral blowers or filters.

External Exhaust
For distances that do not exceed 20 feet (6.1 m), you may choose a unit with integral blower and filters that may be connected to your facility’s duct for venting.

Remote Exhaust
If your facility can supply an exhaust duct and remote blower system that provides an airflow of 550 to 600 cfm (0.260 to 0.283 cu. m/s), a ducted unit will best suit your needs.

 Shandon Grosslab? Senior Grossing Workstation
 Product# Price  Unit  Type  Voltage  
           
 9700      -    Proximity Controlled Elevating, Recirculating 110-120V, 60 Hz, 1 Ph   SELECT  
 97006      -    Manually Controlled Elevating, Recirculating 110-120V, 60 Hz, 1 Ph   SELECT  
 97001      -    Proximity Controlled Elevating, External exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 97007      -    Manually Controlled Elevating, External exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 97002      -    Proximity Controlled Remote exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 97008      -    Manually Controlled Elevating, Remote exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 970022      -    Proximity Controlled Elevating, Recirculating 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700622      -    Manually Controlled Elevating, Recirculating 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700122      -    Proximity Controlled Elevating External exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700722      -    Manually Controlled Elevating, External exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700222      -    Proximity Controlled Elevating, Remote exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700822      -    Manually Controlled Elevating, Remote exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 97003      -    Proximity Controlled Fixed-Height, Recirculating 110-120V, 60 Hz, 1 Ph   SELECT  
 97009      -    Manually Controlled Fixed-Height, Recirculating 110-120V, 60 Hz, 1 Ph   SELECT  
 97004      -    Proximity Controlled Fixed-Height, External exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 970010      -    Manually Controlled Fixed-Height, External exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 97005      -    Proximity Controlled Fixed-Height, Remote exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 970011      -    Manually Controlled Fixed-Height, Remote exhaust 110-120V, 60 Hz, 1 Ph   SELECT  
 9700322      -    Proximity Controlled Fixed-Height, Recirculating 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700922      -    Manually Controlled Fixed-Height, Recirculating 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700422      -    Proximity Controlled Fixed-Height, External exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 97001022      -    Manually Controlled Fixed-Height, External exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 9700522      -    Proximity Controlled Fixed-Height, Remote exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 97001122      -    Manually Controlled Fixed-Height, Remote exhaust 220-240V, 50/60 Hz, 1 Ph   SELECT  
 
Related Products

Accessories and Related Products
 
Shandon Hyperclean™ Filters

 Product#  
   
 9990850  
Select   
Purchase Details
 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Dimensions (H x W x D) :Overall:* 81”-93” x 60” x Varies (205.7 - 236.2 x 152.4 Varies cm) Width shown in chart at right *Height is fixed on Fixed-Height units. Work Surface Height:** 33.5” - 44.5” (85.1 - 115.6 cm) **Customer specified on Fixed-Height units. Right-Hand Sink: 14” x 12” x 6” (35.6 x 30.5 x 15.2 cm)
Weight :Top Piece: Uncrated: 285 lbs. (129.3 kg) Crated: 375 lbs. (170.1 kg) Bottom Piece: Uncrated: 475 lbs. (215.5 kg) Crated: 545 lbs. (247.2 kg)
Electrical Specifications :• Unit is hard wired to facility power. • 110-120V models draw 20 amps and require a separate 15 amp circuit for one hospital-grade duplex ground fault circuit interrupter (GFCI) receptacle. • 220-240V models draw 20 amps including up to 7 amps by the two IEC 320 receptacles with facility-supplied residual current device (RCD) protection required.
Plumbing Specifications :• 3/4" hot and cold water supply lines with shut off valves and 1 1/2" drain line must be supplied. • 1/2" industrial grade flexible hoses with 3/4" female hose fittings are supplied for connection to water supply lines. • 1 1/2" I.D. reinforced flexible hose is provided for connection to facility drain line.
Depth of Shandon Grosslab Units :110-120V, Elevating, Recirculating Models 32.5” (82.6 cm) 110-120V, Elevating, External Exhaust Models 38” (96.5 cm) 110-120V, Elevating, Remote Exhaust Models 38” (96.5 cm) 110-120V, Fixed-Height, Recirculating Models 32.5” (82.6 cm) 110-120V, Fixed-Height, External Exhaust Models 32.5” (82.6 cm) 110-120V, Fixed-Height, Remote Exhaust Models 32.5” (82.6 cm) 220-240V, Elevating, Recirculating Models 32.5” (82.6 cm) 220-240V, Elevating, External Exhaust Models 38” (96.5 cm) 220-240V, Elevating, Remote Exhaust Models 38” (96.5 cm) 220-240V, Fixed-Height, Recirculating Models 32.5” (82.6 cm) 220-240V, Fixed-Height, External Exhaust Models 32.5” (82.6 cm) 220-240V, Fixed-Height, Remote Exhaust Models 32.5” (82.6 cm)
Included with Product :Proximity Controlled Cold/Hot Water Faucet, Table Rinse, and Disposal (proximity controlled units only) — Manually Controlled Cold/Hot Water Faucet, Table Rinse, and Disposal (manually controlled units only) — Stationary Dictation Machine Rack (proximity controlled units only) — Blower (not included with remote exhaust models) — 1/2 hp Disposal — Type 304 Stainless Steel Tabletop and Panels — Upper and Lower Shelves — Hand Spray — Fluorescent Light — Manually Controlled Tea Strainer Faucet — Tea Strainer, Vinyl Cutting Pad, Side Splashes, Formalin Dispenser, Sharps Container, Movable Requisition Rack, Magnifier on Flexible Arm, Magnetic Instrument Bar, Towel Bar and Dispenser, C-fold Towels, Uni-Capsettes™, Formaldehyde Neutralizer Pads, Two Centimeter Rulers
Agency Approvals :UL / cUL (110-120V only); CE (220-240V only)