As the pioneer of fluoride electrode technology, the NEW Thermo Scientific Orion 2109XP fluoride monitor is based on the Standard Test Method for Fluoride Ion in Water (ASTM D 1179-04).
The Orion 2109XP provides the
highest quality fluoride measurements for drinking water required by the Safe Drinking Water Act
(1974) to accurately control between 1.4 to 2.4 ppm. Contact
sales to learn more about the 2109XP fluoride monitor.
Product Detail
Recognized EPA method for fluoride analysis using an
ion selective electrode (ISE)
Eliminates problems with turbidity and suspended
solids in samples, provides true accuracy in measuring total fluoride
Detection limit of 10 ppb - the Orion 2109XP offers
continuous fluoride monitoring in a wide variety of samples
Protect against overfluoridation of samples with
sensitive, selective, reliable and verifiable measurements that provide early
detection of fluoride
Fastest most stable measurements, limiting unnecessary
calibration cycles due to drift with superior Orion fluoride electrode
technology
Minimize operator time and maintenance without use of
complicated moving parts or pumps that often require frequent attention and
expensive spare part expenditures
Advanced user interface with detailed calibration,
measurement and diagnostic logs for early diagnostic and action level
notification, configurable to your facility’s desired level of performance,
and all password protected if preferred
Easy installation has your plant up and running in minutes - the Orion 2109XP is retrofitable to the Orion 1809AO panel mounting footprint
Cat. No.
Reagent Packages
Description
210960XP
Fluoride Consumables Kit
For one year operation, includes (6) x 1 L bottles formic acid reagent and (6) x 2 ft long diffusion tubing with O-rings (182011), fluoride standard solution kit (180940), fluoride sensing electrode (100029), fluoride reference electrode (100056), (1) x 2 oz bottle reference electrode filling solution (181073), O-ring kit (2100OK), check valve (2100VC), pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170)
210960XPF*
Reagent-less Fluoride Consumables Kit
For one year operation, includes (6) x 1 L empty bottles for use with formic acid reagent (182011), (6) x 2 ft long diffusion tubing with O-rings (181060), fluoride standard solution kit (180940), fluoride sensing electrode (100029), fluoride reference electrode (100056),(1) x 2 oz bottles reference electrode filling solution (181073), O-ring kit (2100OK), check valve (2100VC), pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170)
182011
Formic Acid Reagent
60 day supply- includes (1) x 1 L bottle formic acid reagent and (1) x 2 ft long diffusion tubing with O-rings (181060)
182011F*
Reagent-less Formic Acid Reagent Bottle
Includes (1) x 1 L empty bottle for use with formic acid reagent (182011) and (1) x 2 ft long diffusion tubing with O-rings (181060)
182011F6*
Reagent-less Formic Acid Reagent Bottle
Includes (6) x 1 L empty bottles for use with formic acid reagent (182011) and (6) x 2 ft long diffusion tubing with O-rings (181060)
181060
Fluoride Diffusion Tubing
(1) x 2 ft long diffusion tubing and O-rings
181160
High Acid Diffusion Tubing
(3) x 5’8” long thin-walled diffusion tubing and O-rings for high alkalinity samples, 6 month supply
Cat. No.
Fluoride Electrode & Accessories
Description
2109XPEK
Fluoride Electrode Kit
Includes fluoride sensing electrode (100029), fluoride reference electrode (100056), and reference electrode filling solution (181073)
100029
Fluoride Sensing Electrode
For use with 2109XP
100056
Fluoride Reference Electrode
For use with 2109XP, includes reference electrode filling solution (181073)
181073
Reference electrode filling solution
(5) x 2 oz bottles for use with reference electrode (100056)
2100TP
2100 Series Automatic Temperature Probe
With ground (30 kΩ), for use with 2109XP
2001XT
2100 Series Automatic Temperature Probe
With 10 meter extension cable and ground (30 kΩ), for use with 2109XP
2109XPCAL
Calibration Kit
Includes carrying case, 0.5 mL pipette (204847-001), box of pipette tips (204846-001), wash bottle, (1) x 2 oz bottle fluoride standard 1 (100 ppm), (1) x 2 oz bottle fluoride standard 2 (1000 ppm) and (1) inlet filter
180940
Fluoride Standard Solution Kit
Includes (2) x 2 oz bottles of fluoride standard 1 (100 ppm) and (2) x 2 oz bottles of fluoride standard 2 (1000 ppm)
940907
Standard Solution
(1) x 1 pint bottle 100 ppm fluoride standard solution
110902
Standard Solution
(1) x 1 pint bottle 1000 ppm fluoride standard solution
21003M
Extension Cables
(2) x 3 meter cables, for 100029 and 100056 electrodes
Cat. No.
Field Replaceable Units
2100EN
2100 series enclosure
2100FP
Fluidics panel assembly only
2100BP
Steel back panel assembly
2100NV
Inlet valve assembly
2100BV
Bypass/needle valve assembly
2100RG
Regulator assembly
2100DA
Drain and clamp assembly
2100FM
Flow meter assembly
2100RT
Restrictor tube assembly
2100FC
Flow cell assembly
2100PA
Air pump assembly
2100AF
Air filter assembly
2100DV
Diverter valve assembly
2100VC
Check valve
2109RBA
2109XP reagent bottle adapter
2100OK
O-ring kit
2100EC
(2) x 1 meter electrode cables
2100FK115
Fuse kit assembly 115 V
2100FK230
Fuse kit assembly 230 V
2100PS
Power supply assembly
2109XPEP
2109XP electronics faceplate
2109XPSK
includes (1) electronics faceplate (2109XPEP), (1) air pump assembly (2100PA), (1) regulator assembly (2100RG), (2) electrode cable with gland assemblies for sensing and reference electrodes, (1) power supply assembly (2100PS) and (1) fuse kit assembly (2100FK115 and 2100FK230)