ALPHA-7A Alpha Air Monitor

  ALPHA-7A Alpha Air Monitor



AThe ALPHA-7A is a Continuous Air Monitor (CAM) designed to provide early warning to workers exposed to airborne releases of alpha-emitting radionuclides to reduce the internal inhaled dose. It is a modern, PC-based continuous air monitor providing faster and more powerful algorithms for the identification and quantification of airborne releases of alpha-emitting radionuclides, primarily transuranics such as Pu238 and Pu239.
   Product Detail


Features:
  • Fully Standalone
  • Pentium class PC based, Windows 2000 operating system
  • Single configurations accommodates both ambient and stack monitoring applications
  • Flexible detector configuration including positive and negative adjustable bias
  • Removable filter holder cartridge
  • High speed connections via 10 base T Ethernet connection
  • RadNet Compliant
  • Relay contacts provide for normal/fail, alert and alarm conditions
  • 4-20 mA analog input and output capacity
  • High visibility display for status and messages
  • Calculates isotopic activity by mapping the peak(s) rather than using regions of interest (ROI)
  • Spectrums updated once per second
  • New isotopes easily added from the library
  • New isotopes can be added to the library using any ODBC database manager
  • Automatic gain control based on naturally occuring peaks
  • Tracks alpha-emitting daughter products
  • Full-Featured Windows-based client software presents grahpical displays of spectrum and status to any networked or local PC
 
Purchase Details
SKU : ALPHA-7A 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Services
  • Critical Depot Service Agreement
  • Retrofit and Refurbishment Service
  • Specifications:
    Detector :Solid state, 490 sq mm active area
    Efficiency :Pu-239 17% (4 pi)
    Sensitivity :2 DAC-hours (pu-239) with 60 minute analysis
    Sample Rate :1 CFM (typical) to 2 CFM
    Dimensions :14 x 14 x 6 inches
    Weight :Approximately 23 pounds (not including pump)
    Connections :RJ-45 for 10-Base-T Ethernet (calibration and/or networking); Keyboard (local control of the Alpha-7); External video (local view of the spectrum and for calibration); Terminal blocks for analog input, analog output, and relays
    Power :90 to 264 VAC, less than 100 Watts
    Air Inlet :1 inch tubing
    Note on Tubing :Compression fitting required for use with sampling tubing
    Analog Inputs :0 or 4 to 20 mA analog output which can be assigned to various measured items, for example Slow Concentration, Fast Concentration, Sample Flow Rate, Stack Flow Rate, Relay contacts for Alarm, Fail, Alert, and High Activity Alarms
    Pump :Suggested in the RAP-1 (or RAP1-220 for 220 V operation).
    Automated Calibration Routines :Monitors up to 8 isotopes simultaneously; Separate alarms and analysis times for each isotope; Smart remote in-line or radial entry sampling heads; Up to 1000 feet between display and sample head
    Options :Calibration Software; Client Software; Filter Holder Assembly for In-line head; Wall Mount Bracket; Filter Paper; Calibration Source Holder for In-line Head; In-line Adaptor, FG55194, for connecting sample tubing; Calibration Sources