Explosion Proof Gas Detection, FX-SMT Transmitters
The FX-SMT Intelligent Single Gas Detection Transmitter detects oxygen, combustible and various toxic gases is loaded with industry features. These transmitters come standard with non-intrusive calibration which eliminates the need to declassify hazardous areas, a user adjustable "calibration reminder" message.
Product Detail
The FX-SMT Intelligent Single Gas Detection Transmitter is loaded with industry features. These transmitters come standard with non-intrusive calibration which eliminates the need to declassify hazardous areas, a user adjustable "calibration reminder" message. Smart sensor replacement assemblies available for plug in operation.
This single gas transmitter can be configured for the detection of combustibles, AsH3, B2H6, Cl2, Cl02, CO, F2, HCl, HCN, HF, H2S, NH3, NO, NO2, O2, O3, PH3, SiH4 or SO2.
Features:
Non-intrusive calibration via a magnetic wand eliminates the need to declassify hazardous areas
User adjustable "calibration reminder" message
Pre-calibrated sensors for quick plug-in operation
Using an optional adapter, oxygen and toxic gas detectors can be mounted up to 25 ft. away from the transmitter; 200 ft. for combustible gases (no adapter required)
Connect to Thermo Scientifics (formerly GasTech's) controllers, PLC (Programmable Logic Controllers) or DCS (Distributive Control System)
Industry standard, 4 to 20 mA output
Housed in a NEMA 4X, copper-free aluminum enclosure (weather & explosion-proof)
User friendly - simple to operate
Economical
Gas:
Part Number:
Range:
Calibration Kit:
Replacement Sensor:
Replacement Smart Sensor:|
Ammonia (NH3)
67-0024-09
0 - 100 ppm in 1 ppm increments
81-6412-05
65-2431-07
65-2432-07
Arsine (AsH3)
67-0024-13
0 - 1.00 ppm in 0.01 ppm increments
81-6412-06
65-2431-08
65-2432-11
Carbon Monoxide (CO)
67-0024-01
0 - 500 ppm in 1 ppm increments
81-6413-09
65-2425-01
65-2432-14
Chlorine (Cl2)
67-0024-04
0 - 10.0 ppm in 0.1 ppm increments
81-6412-02
65-2431-01
65-2432-01
Chlorine Dioxide (ClO2)
67-0024-16
0 - 2.00 ppm in 0.01 ppm increments
See Note 1
65-2431-11
65-2432-13
Combustibles
67-0021-01
0-100% LEL
81-6413-XX
61-0101
N/A
Diborane (B2H6)
67-0024-18
0 - 1.00 ppm in 0.01 ppm increments
81-6412-06
65-2431-08
65-2432-18
Fluorine (F2)
67-0024-07
0 - 10.0 ppm in 0.1 ppm increments
81-6412-02
65-2431-01
65-2432-01
Hydrogen Chloride (HCl)
67-0024-05
0 - 30.0 ppm in 0.1 ppm increments
81-6412-03
65-2431-04
65-2432-04
Hydrogen Cyanide (HCN)
67-0024-08
0 - 50.0 ppm in 0.1 ppm increments
81-6412-04
65-2431-02
65-2432-02
Hydrogen Fluoride (HF)
67-0024-06
0 - 10.0 ppm in 0.1 ppm increments
81-6412-02
65-2431-05
65-2432-05
Hydrogen Sulfide (H2S)
67-0024-02
0 - 100 ppm in 1 ppm increments
81-6412-01
65-2425-02
65-2432-15
Nitric Oxide (NO)
67-0024-14
0 - 100 ppm in 1 ppm increments
81-6412-07
65-2431-03
65-2432-03
Nitrogen Dioxide (NO2)
67-0024-15
0 - 20.0 ppm in 0.1 ppm increments
81-6412-08
65-2431-10
65-2432-12
Oxygen (O2)
67-0024-03
0 - 30.0 % Vol. in 0.1% Vol
81-6413-08
65-1061
65-2432-16
Ozone (O3)
67-0024-12
0 - 1.00 ppm in 0.01 ppm increments
See Note 2
65-2431-09
65-2432-10
Phosphine (PH3)
67-0024-10
0 - 1.00 ppm in 0.01 ppm increments
81-6412-06
65-2431-08
65-2432-08
Silane (SiH4)
67-0024-11
0 - 20.0 ppm in 0.1 ppm increments
81-6412-11
65-2431-08
65-2432-09
Sulfur Dioxide (SO2)
67-0024-17
0 - 20.0 ppm in 0.1 ppm increments
81-6412-09
65-2420-02
65-2432-17
Note1: For ClO2 calibration, Thermo Scientific uses an Advanced Calibration Designs, Inc. Model 300 (Phone: 520.290.2855)
Note2: For O3 calibration, use the Model 165 (Phone: 508.520.0430)
Explosion Proof Gas Detection, FX-SMT Transmitters
AsH3, B2H6, Cl2, ClO2, CO, F2, HCl, HCN, HF, H2S, NH3, NO, NO2, O2, O3, PH3, SiH4, or SO2
Analog Output :
4-20 mA
Relay Outputs (hydrocarbon only) :
Optional Local Alarm Relay Module contains three SPDT (Form C) relays housed in a separate explosion-proof junction box. Each relay rated at 10A/30 VDC, 10A/250 VAC
Accuracy :
+/- 10% of reading
Repeatability :
+/- 5% of reading
Operating Temperature :
-4 F to 113 F (-20 C to 45 C)
Humidity :
0 to 95% RH, non-condensing
Alarms :
Low/High Gas and Sensor Failure indicator with visual LED
Display :
1 x 16 character LCD
Alarm Delay :
User selectable
Input Power :
10-28 VDC, loop-powered
Dimensions :
6.2 in (158 mm) L x
4.6 in (117 mm) H x
10 in (254 mm) W
Weight :
5 lbs (2.3kg)
Case Materials :
Aluminum - high impact , chemical, EMI or RFI resistant
Approvals :
UL Classified for Class l, Division 1, Groups B,C, & D (combustible version), Explosion/ Fire proof housing