Bench-top models are ergonomically designed to be low to the counter.
Abundant fluorescent light is directed to the work surface.
Rapid positive drainage.
Vacuum breaker-protected water supply.
Hands-free faucet control on selected benchtop models uses an infrared signal to activate cold water; also has manual override capability.
Three air processing options: Recirculating, External Exhaust, or Remote Exhaust.
Fume removal is efficient and quiet.
Noise levels measure less than 65 decibels.
Appliances plug into the unit for convenient use.
Two hospital-grade duplex ground fault circuit interrupter (GFCI) receptacles on 110-120V units.
Four IEC 320 receptacles on 220-240V units.
Facility-supplied residual current device (RCD) is required for 220-240V units.
Back draft design for efficient capture of fumes across the work surface.
Programmable microprocessor allows clock time to be changed or the filter replacement alarm to be reset.
Flat stainless steel work surfaces include three removable perforated grid plates on bench-top models.
Each unit comes complete with a magnetic tool bar, two integral centimeter rulers, tea strainer, and paper towel dispenser.
Installation is quick and easy.
Movable acrylic splash shield protects the user from sprays and splashes while dissecting specimens.
Bench-top models can be configured as stand-alone units with the use of the optional stand (No. 10456).
Choosing the Exhaust System to Fit Your Lab Recirculating For existing labs or labs without facility exhaust, it may be necessary to filter and recirculate the air. Specify a unit with integral blowers or filters.
External Exhaust For distances that do not exceed 20 feet (6.1 m), you may choose a unit with integral blower and filters that may be connected to your facility’s duct for venting.
Remote Exhaust If your facility can supply an exhaust duct and remote blower system that provides an airflow of 550 to 600 cfm (0.260 to 0.283 cu. m/s), a ducted unit will best suit your needs.
Overall: Recirculating: 45.75” x 48” x 28” (116.2 x 121.9 x 71.1 cm)
External: 52.75” x 48” x 28” (134 x 121.9 x 71.1 cm)
Remote: 52.75” x 48” x 28” (134 x 121.9 x 71.1 cm)
Work Surface Height: 1.75” (4.4 cm) above benchtop
Recommended Depth: 29” (73.7 cm) from front of unit to wall
Right-Hand Sink: 18” x 6” x 4” (45.7 x 15.2 x 10.2 cm)
Weight :
Uncrated: 300 lbs. (136.1 kg) Crated: 350 lbs. (158.8 kg)
Electrical Specifications :
• One IEC 320 Power Entry Module and one point-of-use power cord.
• 110-120V and 220-240V models require facility receptacles with 15
amp circuits for each power cord.
• 110-120V models draw 15 amps including the two hospital-grade
duplex ground fault circuit interrupter (GFCI) receptacles.
• 220-240V models draw 15 amps including the four IEC 320
receptacles with facility-supplied residual current device (RCD)
protection required.
Plumbing Specifications :
• One 1/2” industrial-grade flexible hose with 3/4” female hose fittings is
supplied for connection to cold water supply lines.
• One 3/4” NPT connection and 1” I.D. reinforced flexible hose is supplied
for connection to facility drain line.
____________________ :
____________________
Stand-alone Model Specifications :
-
Dimensions (H x W x D) :
Overall: Recirculating: 78.5” x 48” x 28” (199.4 x 121.9 x 71.1 cm)
External: 85.5” x 48” x 28” (217.2 x 121.9 x 71.1 cm)
Remote: 85.5” x 48” x 28” (217.2 x 121.9 x 71.1 cm)
Work Surface Height: 36” (91.4 cm)
Recommended Depth: 29” (73.7 cm) from front of unit to wall
Right-Hand Sink: 14” x 12” x 9.75” (35.6 x 30.5 x 24.8 cm)
Weight :
Uncrated: 500 lbs. (226.8 kg) Crated: 600 lbs. (272.2 kg)
Electrical Specifications :
• Two IEC 320 Power Entry Modules and two point-of-use power cords.
• 110-120V and 220-240V models require facility receptacles with 15
amp circuits for each power cord.
• 110-120V models draw 15 amps including the two hospital-grade
duplex ground fault circuit interrupter (GFCI) receptacles.
• 220-240V models draw 15 amps including the four IEC 320
receptacles with facility-supplied residual current device (RCD)
protection required.
Plumbing Specifications :
• Two 1/2” industrial-grade flexible hoses with 3/4” female hose fittings are
supplied for connection to cold and hot water supply lines.
• 1 1/2” I.D. reinforced flexible hose is supplied for connection to facility
drain line.