CQCS Network QC & Traceability System

  CQCS Network QC & Traceability System



The CQCS Centrifugation Quality Control System ensures conformity with ISO 9000 and GLP/cGMP standards by providing traceability of samples, machines and operators during the run. Operating on up to 32 centrifuges (including a combination of  KR4i, KR4.22 and KR25i) in a network, CQCS™ also acts in providing a valuable aid to preventative maintenance.

   Product Detail


Operator error eliminated: Instrument data is provided by the instrument; sample data is provided by bar code reader, date and time data is provided by the PC.

 

Easy to use: Staff can be trained in one short session. Training is also provided on interactive CD-ROM.

 

Choice of sample ID capture:
Single Step Mode identifies samples as they are loaded into the centrifuge.

Two Step Mode identifies individual samples as they are loaded into an identified multiple sample holder (e.g. blood bags put into a liner). The multiple sample holder is later identified as it is put into the centrifuge (the PC associates the Sample-Holder and Holder-Centrifuge data to create the Sample-Centrifuge association). Samples can thus be prepared in the preferred environment.

 

Supervisor facility: Can view basic operation of 15 machines in parallel on a single screen.

 

Real time detailed monitoring: View all set and actual parameters plus all sample, instrument and operator identities.

 

Convenient presentation: Choice of on-screen or printout (automated, if programmed) including the graph of the run and all sample, instrument, operator and run data. User naming of program by application name (or any other ID).

 

Powerful search tool: Can search by sample ID, date and time, run condition (e.g. speed error), centrifuge number (in the network), centrifuge serial number, program number, program (application) name, operator ID, filename.

 

High operating security: Three access levels (Operator, Manager, Engineer) with password protection.

 

Automated data security: Automatic file creation and data storage at run end. Pre-programmed back-up on any other computer. Restore from back-up if data loss on lab PC.

 

Results usable by LIMS: Any Lab Information Management System permitted by the lab manager can come and take copies of the data.

 

Versatile data format: Data is stored in comma delimited format. All LIMS, spreadsheet and database programs can read the data.

 

Centralization of data analysis: A single PC anywhere in the world can be defined as a centralized back-up site; data from several sites can thus be analyzed by a Group Qualiy Control Manager.

 

Conformity with quality standards: Any modification of data automatically invokes file saving under a new and different name. Original, raw data is always available.

 

Full alarm features: On screen alarm. E-mailing to up to three e-mail addresses (inside or outside of the establishment), user-defined individually for each significant alarm condition.

Networks over long distance: RS485 interface permits 1650-3300 ft (500-1000 meters) total line length connecting centrifuges in various labs in the building.

 

Aid to maintenance: Run analysis can detect tendency towards a fault condition enabling lower cost preventative maintenance at a convenient time instead of down time and loss of production.

 

 CQCS Network QC & Traceability System
 PRODUCT# Price  Equipment  
       
 11178410      -    For KR4i, first unit   SELECT  
 11178411      -    For KR4i, other units   SELECT  
 11178401      -    For KR4.22, other units   SELECT  
 
Verwandte Produkte

Zubehör und ähnliche Produkte
 
Jouan KR 25i Superspeed Floor Model Centrifuge

 PRODUCT#
 
 11177391
 11177390
KR4i Centrifuge

 PRODUCT#  
   
 11178160  
Select   
 11178162  
Select   
Purchase Details
Request Quote
Contact Sales
 Sales
  Service
 
Specifications:
Max Machines :Up to 32 centrifuges
Compatible Centrifuges :KR25i, KR4i, KR4.22
Sample Data Capture :Upon loading the centrifuge or upon loading the sample holder (then holder upon loading centrifuge)
Data Storage :Automatic on local PC, programmable backup on any remote PC world-wide
Data Storage Format :Comma delimited, readable by any LIMS, spreadsheet or database software.
Data Protection :3 operating access levels with password. Data recoverable from back-up PC. Modified data always stored under a new name.
Search Parameters :Sample ID, date & time, run condition, centrifuge number in network, centrifuge serial number, program number, program (application) name, operator ID, filename.
Sample & Centrifuge Protection :Ability to call service back-up within 5 minutes of fault condition appearing.
Minimum PC Specification : 
   Processor :Pentium 166MHz, 32 Mb RAM
    Hard Disk :200 Mb Hard Disk
   Screen :SVGA - 800 x 600 pixels
   Ports :2 x serial
   Modem :56kb with internet access configured
   Installation Device :CD-ROM reader