PSM-400MPX Particle Size Analyzer

  PSM-400MPX Particle Size Analyzer



The Thermo Scientific PSM-400MPX Particle Size Monitor uses ultrasonic attentuation technology to provide particle size analysis of a mineral slurry stream. Continuous, real-time feedback will instantly alert the plant manager to process upsets, allowing a quck reaction to lessen the impact. This helps to maximize mill throughput, product quality and energy efficiency.

   Product Detail


Measures and Reports

  • 5 particle size fractions simultaneously
  • Handles p80s between 280 and 25 microns
  • Slurry density or percent solids
  • Period averages, trends and historical data logging
  • Up to three streams

Benefits

  • Links with AnStat-220T and SamStat-20T as the source of the sample
  • Requires no dilution of slurry stream
  • Modern user interface and communication links with the plant network
  • Skid mounted for ease of installation
  • Detects process upsets such as cyclone disturbances

 

 
Related Products
 Product# Product Name Image  
  PID-22507   Anstat-220
  Select  
  PID-19514   SamStat-20 Representative Slurry Sampling Station
  Select  
 
Purchase Details
SKU : PSM-400MPX 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Analysis Performance :Specifications
Number of streams :Standard one stream. (Optional 2 or 3 stream multiplexed at extra cost). Up to 5 size fractions and percent solids for each stream may be analyzed. Distributions with top size no greater than 1mm, and P80 of 295 microns (µ) down
Size fractions ranges :Must be sub-sets of the overall measurement range and can be +295µ down to -8µ.
Sample Flow-rate required :2.0 ? 4.5 m3/h of statistically correct sample from process (e.g. by Reverse Flow Sampler or Thermo ?SamStat?). Slurry can be 4 to 60% solids by wt., and solids S.G. of 2.0 to 5.5.
Ultrasonic transmitters :6 frequencies selected at design stage to suit the process particle-size and % solids range
Accuracy :Typically 0.75% absolute one sigma at the target grind for both size and percent solids. Note: independent of particle shape, mineralogy and matrix variations.
Utilities Required :Specifications
Control and Display Module: Electrical Power :110 to 130VAC; 50/60 Hz; 0.1 kW with water heater off, or 0.8 kW with water heater on.
Instrument Air :Instrument-quality Air (clean and dry to 0.1 microns with dew point <2°C). Pressure nominally 690kPa (100psi) 450kPa to 800kPa.
Standardisation Water :Only clean, fresh, potable water may be used, Volume is dependent upon frequency of standardization; normally once per shift, requiring about 12 litres (3 gallons) per day.
Sample Conditioner: Electrical Power :3.8 KW (5 HP), 50/60 Hz, 190-575 VAC, 3-phase, heavy-duty motor
Sample Acquisition (vacuum) :Water Flow to eductor/aspirator needs supply at 275-550kPa (40-80 psi) and a flow rate of 2.7 m3/h. (Can be re-circulated as an option).
Communications Links :Specifications
Internal: PSM-400 to PC :Each unit requires two pairs of shielded- twisted pair (1.5mm) instrumentation cable. Maximum length 1.0km for point to point current-loop to RS-232 connection.
External: PSM-400 to Control System :4 to 20mA analog current loops (up to 16 x 12- bit channels)
PC to customer control system and LAN :Ethernet link using TCP/IP protocol including OPC or EIA RS-232, RS-422 serial lines (MODBUS).
Off site Modem :One data-quality phone line or VPN internet link
Dimensions (For standard MPX) :1840 height 1770 length 1120 width 700kg weight