Discontinued - TEOM Series 7000

  Discontinued - TEOM Series 7000



This product has been discontinued. See the notice at the left for more information. The replacement product is the Model 445 Opacity Monitor.

The TEOM Series 7000 Source Particulate Monitor is an in-situ device that provides a direct measurement of the particulate matter (PM) concentration in a stack.

This product is no longer offered.

   Product Detail


The TEOM Series 7000 Source Particulate Monitor promises to revolutionize the way in which source particulate matter (PM) concentrations are determined. Like conventional PM stack sampling methods, it collects particles from the source onto a filter for gravimetric analysis. But instead of having to transport collection filters to a laboratory for weighing, the monitor performs a direct measurement of the collected particulate mass on-line. The instrument's mass transducer and filter are located in-situ to minimize losses of PM due to sample sample transport.

The monitor substantially reduces the dependence of stack PM concentration results upon the individual operator, allowing for much higher consistency. The instrument generates high-quality source PM concentration information through the following features:

  • PM sample collection and weighing using the same hardware in real time. The PM sample no longer needs to be transported to a laboratory for weighing.
  • Automated computation of moisture content, molecular weight and flue velocity.
  • Software provides guidance for the test program, and enables flexible reporting of results.
  • Advanced diagnostics ensure data validity.

Like traditional stack particulate sampling methods, the TEOM Series 7000 monitor determines the flue velocity, collects particles isokinetically on a filter, and performs a direct measurement of their mass.

  • No laboratory conditioning of filters
  • Single-stage sampling and analysis
  • Direct mass measurement
  • In-stack analysis
  • Real-time results
  • Superior precision and accuracy
 
Related Products
 Product# Product Name Image  
 
EID-101307
10
 
Opacity Monitor, Model 445
  Select  
 
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Mass Concentration Resolution :0.2 mg/m³
Minimum Detectable Limit :0.4 µg
Accuracy :±5%
Precision :2.5% of accumulated mass
Ambient Temperature Range :-30 to +50 °C
Source Gas Temperature Range :up to 200 °C
Source Gas Flow Rate :up to 90 ft/sec (27 m/sec)