Welcome Guest from United States
Sign In Change Country
  0 Items
Search:
Thermo Scientific Method 8270 C/D GC-MS Productivity Solution

  Thermo Scientific Method 8270 C/D GC-MS Productivity Solution



Developed to provide optimal performance of US EPA Methods 8270C and 8270D on the Thermo Scientific DSQTM II GC/MS system, the 8270 C/D Productivity Solution combines the hardware, software, consumables and methods to provide a comprehensive solution for the GC/MS analysis of semivolatile organics. Achieve single digit precision across the broadest range of compounds in the shortest amount of time, and gain a true competitive edge with increased productivity and sample throughput.
   Product Detail


The Thermo Scientific 8270 C/D Productivity Solution integrates the DSQ II GC/MS system with the software, methods and consumables needed to perform GC/MS analysis of semivolatiles according to US EPA Method 8270C and 8270D. The 8270 Productivity Solution redefines traditional method development and validation processes by providing pre-developed methods that ensure immediate success and productivity.

PRODUCT FEATURES

The 8270 Productivity Solution provides a turn-key package that allows new users to become effective immediately, while allowing experienced operators to focus on relevant activities, rather than performing tasks such as diluting standards. A full complement of methods, templates for the EnviroLabTM Forms 2.0 software that comes with the solution, and two weeks' worth of Thermo Scientific consumables carefully selected and validated to conform to the method quality control criteria are included in the package. Extensive method development and validation steps were taken to ensure that the 8270 Productivity Solution provides the optimum balance of performance and productivity.

DSQ II GC/MS System

The Thermo Scientific DSQ II single quadrupole GC/MS system provides the heart of the 8270 Productivity Solution. 

  • Fast full scan rates (>11,000 amu/sec) -- use fast chromatography for increased sample throughput with high spectral quality and rapid data acquisition to fully characterize narrow peaks
  • Use a split injection technique for improved chromatography, enhanced resolution of early-eluting peaks, and extended instrument uptime, while still achieving lower detection limits with the DuraBriteTM source 
  • Detect and quantify samples across a broad concentration range, minimizing dilutions and repeated samples with the DynaMax XR detection system
  • TRACE GC UltraTM -- fast heating and cooling rates ensure optimum productivity
  • AS 3000 or the TriPlusTM AS autosampler systems -- precise, effective sample injections for lower detection limits

EnviroLab Forms 2.0 Software, Methods, and Templates

EnviroLabTM Forms 2.0 is a workflow-oriented software package developed specifically for the needs of the environmental laboratory. The 8270 Productivity Solution includes a full set of methods and templates for EnviroLab Forms.

  • Integrated method management, batch programming, data review, and reporting functions streamlines daily functions
  • Methods and templates make routine operations straightforward
  • Numerous pre-configured reporting options allow users to easily select desired report formats
  • Data flagging to highlight out-of-control data simplifies review
  • Complete set of validation data demonstrates method performance

Thermo Scientific Consumables

A complete set of Thermo Scientific consumables have been performance-matched to US EPA Method 8270C/D requirements, ensuring the best response for a compound list that includes 120 base/neutral/acid (BNA) compounds and internal standards. 

  • Save time and money with pre-diluted and stock standard sets to easily perform initial calibration, performance checks, and continuing calibration evaluations
  • Specially-engineered TRACETM TR-8270 analytical column provides best resolution and least activity to the broad range of target compounds
  • Deactivated injection port liners reduce activity in the injection port for challenging compounds
  • Autosampler syringes for precise liquid injections
  • Low-bleed septa offer rugged performance with minimal background

Comprehensive Documentation

Be productive with your new DSQ II GC/MS system and 8270 Productivity Solution right out of the box by using the full set of documentation provided in the package. A Quick Start Guide highlights basic operations, while a more detailed How-To Manual offers additional information. The comprehensive Standard Operating Procedure (SOP) thoroughly covers the use and operation of the 8270 Productivity Solution, and can be used as a starting point for developing required operating manuals. Training is simplified and consistent from operator to operator and from instrument to instrument. A Quick Reference CD incorporates reorder information along with training, and a validation data CD includes the complete data set for the factory validation of the 8270 Productivity Solution.

 

Related Products

 Product#  Product Name Image  
         
 IQLAAAGAAHFAGJMAAH   AI 3000/AS 3000 Series II Autosamplers 
  SELECT  
 IQLAAAGAAJFACGMAFV   DSQ II Single Quadrupole GC/MS with FOCUS GC 
  SELECT  
 SID-ENVIROLABGCMS   EnviroLab™ Forms 2.0 Software 
  SELECT  
 IQLAAAGAAHFAFUMAMR   TRACE GC Ultra™ 
  SELECT  
 IQLAAAGAAJFAGKMAOA   Thermo Scientific DSQ II Single Quadrupole GC/MS 
  SELECT  
 IQLAAAGAAHFACMMAMU   TriPlus™ Autosampler 
  SELECT  
 
Purchase Details
SKU : IQLAAAGAAJFAGLMAOD 
Request Quote
Product Contact
 Sales Contact
  Service Contact