Orion 2109XP Fluoride Monitor

  Orion 2109XP Fluoride Monitor



As the pioneer of fluoride electrode technology, the NEW Thermo Scientific Orion 2109XP fluoride monitor is based on the Standard Test Method for Fluoride Ion in Water (ASTM D 1179-04).

The Orion 2109XP provides the highest quality fluoride measurements for drinking water required by the Safe Drinking Water Act (1974) to accurately control between 1.4 to 2.4 ppm.  Contact sales  to learn more about the 2109XP fluoride monitor.

   Product Detail


  • Recognized EPA method for fluoride analysis using an ion selective electrode (ISE)
  • Eliminates problems with turbidity and suspended solids in samples, provides true accuracy in measuring total fluoride
  • Detection limit of 10 ppb - the Orion 2109XP offers continuous fluoride monitoring in a wide variety of samples
  • Protect against overfluoridation of samples with sensitive, selective, reliable and verifiable measurements that provide early detection of fluoride
  • Fastest most stable measurements, limiting unnecessary calibration cycles due to drift with superior Orion fluoride electrode technology
  • Minimize operator time and maintenance without use of complicated moving parts or pumps that often require frequent attention and expensive spare part expenditures
  • Advanced user interface with detailed calibration, measurement and diagnostic logs for early diagnostic and action level notification, configurable to your facility’s desired level of performance, and all password protected if preferred
  • Easy installation has your plant up and running in minutes - the Orion 2109XP is retrofitable to the Orion 1809AO panel mounting footprint

 Cat. No.  Reagent Packages  Description
 210960XP  Fluoride Consumables Kit

For one year operation, includes (6) x 1 L bottles formic acid reagent and
(6) x 2 ft long diffusion tubing with O-rings (182011), fluoride standard solution kit (180940), fluoride sensing electrode (100029), fluoride reference electrode (100056), (1) x 2 oz bottle reference electrode filling solution (181073), O-ring kit (2100OK), check valve (2100VC), pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170)

 210960XPF* Reagent-less Fluoride Consumables Kit

For one year operation, includes (6) x 1 L empty bottles for use with formic acid reagent (182011), (6) x 2 ft long diffusion tubing with O-rings (181060), fluoride standard solution kit (180940), fluoride sensing electrode (100029), fluoride reference electrode (100056),  (1) x 2 oz bottles reference electrode filling solution (181073), O-ring kit (2100OK), check valve (2100VC), pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170)

182011

Formic Acid Reagent

60 day supply- includes (1) x 1 L bottle formic acid reagent and (1) x 2 ft long diffusion tubing with O-rings (181060)

182011F*

Reagent-less Formic Acid Reagent Bottle Includes (1) x 1 L empty bottle for use with formic acid reagent (182011) and (1) x 2 ft long diffusion tubing with O-rings (181060)

182011F6*

Reagent-less Formic Acid Reagent Bottle Includes (6) x 1 L empty bottles for use with formic acid reagent (182011) and (6) x 2 ft long diffusion tubing with O-rings (181060)

181060

Fluoride Diffusion Tubing

(1) x 2 ft long diffusion tubing and O-rings

181160

High Acid Diffusion Tubing

(3) x 5’8” long thin-walled diffusion tubing and O-rings for high alkalinity samples, 6 month supply

 

 Cat. No. Fluoride Electrode & Accessories  Description
 

2109XPEK

Fluoride Electrode Kit

Includes fluoride sensing electrode (100029), fluoride reference electrode (100056), and reference electrode filling solution (181073)

100029 Fluoride Sensing Electrode

For use with 2109XP

100056

Fluoride Reference Electrode

For use with 2109XP, includes reference electrode filling solution (181073)

181073

Reference electrode filling solution (5) x 2 oz bottles for use with reference electrode (100056)

2100TP

2100 Series Automatic Temperature Probe

With ground (30 kΩ), for use with 2109XP

2001XT

2100 Series Automatic Temperature Probe

With 10 meter extension cable and ground (30 kΩ), for use
with 2109XP

2109XPCAL

Calibration Kit Includes carrying case, 0.5 mL pipette (204847-001), box of pipette tips (204846-001), wash bottle, (1) x 2 oz bottle fluoride standard 1 (100 ppm), (1) x 2 oz bottle fluoride standard 2 (1000 ppm) and (1) inlet filter

180940

Fluoride Standard Solution Kit Includes (2) x 2 oz bottles of fluoride standard 1 (100 ppm) and (2) x 2 oz bottles of fluoride standard 2 (1000 ppm)

940907

Standard Solution

(1) x 1 pint bottle 100 ppm fluoride standard solution

110902

Standard Solution

(1) x 1 pint bottle 1000 ppm fluoride standard solution

21003M

Extension Cables

(2) x 3 meter cables, for 100029 and 100056 electrodes

 

 Cat. No. Field Replaceable Units
2100EN

2100 series enclosure

2100FP

Fluidics panel assembly only

2100BP

Steel back panel assembly

2100NV

Inlet valve assembly

2100BV

Bypass/needle valve assembly

2100RG

Regulator assembly

2100DA

Drain and clamp assembly

2100FM

Flow meter assembly

2100RT

Restrictor tube assembly

2100FC

Flow cell assembly

2100PA

Air pump assembly

2100AF

Air filter assembly

2100DV

Diverter valve assembly

2100VC

Check valve

2109RBA

2109XP reagent bottle adapter

2100OK

O-ring kit

2100EC

(2) x 1 meter electrode cables

2100FK115

Fuse kit assembly 115 V

2100FK230

Fuse kit assembly 230 V

2100PS

Power supply assembly

2109XPEP

2109XP electronics faceplate

2109XPSK

includes (1) electronics faceplate (2109XPEP), (1) air pump assembly (2100PA), (1) regulator assembly (2100RG), (2) electrode cable with gland assemblies for sensing and reference electrodes, (1) power supply
assembly (2100PS) and (1) fuse kit assembly (2100FK115
and 2100FK230)

 Orion 2109XP Fluoride Monitor
 Product# Price  Fluoride Monitor Packages  
       
 2109XP      -    Fluoride Monitor Instrument Only   SELECT  
 2109XPEN      -    Fluoride Monitor with Protective Enclosure   SELECT  
Purchase Details
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Response Time :Reach 95% of final reading within 2 minutes of injecting a standard solution
Units Displayed :ppb, ppm (auto ranging)
Temperature :5 to 35 ˚C
Total alkalinity : less than 200 ppm CaCO3
Inlet pressure :8 to 100 psig
Flow rate :40 mL/min nominal set by pressure regulator
Sample inlet :1/4” NPTF tube fitting
Sample drain :3/4” NPT male
Grab sampler supported :YES
Analog output :Galvanically isolated
Number of analog outputs :2, one dedicated to fluoride, one to temperature; shared ground
Output selections :0 - 20 mA or 4 - 20 mA
Programmable range :YES
Log & linear output options :YES, user selectable
Alarm outputs :3
Number of relay outputs :3
Maximum relay load :250 VAC, 5 A, 30 VDC
Min/Max Value Alarm :YES
Error Alarm :YES
Calibration/offline alarm :YES
Programmable min & max values :YES
Electronics Dimensions :144 x 144 x 187 mm
Entire system dimensions :65 x 45 x 27 cm (26” x 17” x 11”) Fits on 1809AO panel mounting footprint.
Input :85-132 or 170-264 VAC
Self-test & diagnostics :YES
Password protection :YES
Programmable alarms :High, low, error, calibration/offline
Waterproof enclosure :IP66 & NEMA 4X
Regulatory and Safety :CE, CSA, UL, FCC Class A limits
Case Material :Valox 364