Accurate detection allows precise ammonia control with confidence - maintain proper chemical feed levels without the guess work or excessive operating cost
Repeatable and verifiable ammonia measurements using superior Orion ammonia electrode technology for the highest level of performance available
Designed for ammonia specificity, the unique chemistry provides unsurpassed results across a wide range without the pitfalls of pH and conductivity "bottom out effects"
Easy to operate and calibration - the Orion 2110XP walks you through the step-by-step calibration process, ensuring a successful calibration the first time and every time
Product Detail
The Thermo Scientific Orion 2110XP ammonia monitor provides continuous, direct and precise measurements for the control and optimization of boiler ammonia levels. Reduce operational costs while producing the highest purity steam with ease of use for results that only the Orion 2110XP can provide.
The Orion 2110XP indicates the most sensitive changes in ammonia concentration for condensate and feedwater optimization and control. Often plants will use conductivity or pH to control ammonia, however these methods are negatively influenced by other ionic species from the boiler treatment chemicals in the sample. Our monitor maintains sensitivity and accuracy at high and low levels to produce rapid results with the utmost confidence.
The 2110XP provides stable and drift-free measurements with minimal maintenance and eliminates the need for frequent calibrations, saving you time and money.
Ammonia detection range of 0 to 10 ppm for the most direct, accurate and precise results available
Continuous online measurement ensures real-time information for optimum contorl of the ammonia feed without excessive operating costs
Selective and sensitive for ammonia, our system surpasses the performance of other systems that have the limitations of pH and conductivity to track real-time boiler ammonia levels
Cat. No.
Reagent Kits & Accessories
Description
181030
Acetic Acid Reagent
For 6 month operation, includes (1) x 1 L bottle of acetic acid reagent (does not include tubing, purchase 150060 seperately)
150060
Diffusion Tubing Kit
(1) x 4 ft diffusion tubing assembly with O-rings
150063
Diffusion Tubing Only
(1) x 100 ft thick-walled diffusion tubing (does not include O-ring, purchase 210OK separately)
181040
Ammonia Standard Solutuion Kit
Includes (1) x 2 oz bottle of standard 1 (191 ppm) and (1) x 2 oz bottle of standard 2 (1920 ppm)
181060
Chloride Diffusion Tubing
(1) x 2 ft long diffusion tubing and O-rings
Cat. No.
Ammonia Electrode & Accessories
Description
100047
Amonia sensing electrode
With screw cap, for use with 2110XP
210056
Ammonia Reference Electrode
With screw cap, for use with 2110XP, includes reference electrode solution (181073)
181073
Reference Electrode Filling Solution
(5) x 2 oz bottles for use with reference electrode (210056)
2100TP
2100 Series Automatic Temperature Probe
With ground (30 kΩ), for use with 2117XP
2001XT
2100 Series Automatic Temperature Probe
With 10 meter extension cable and ground (30 kΩ), for use with 2117XP
21003M
Extension Cables
(2) x 3 meter cables, for 100025 and 100057 electrodes
Cat. No.
Field Replaceable Units
2100EN
2100 series enclosure
2100FP
Fluidics panel assembly only
2110XPEP
2110XP electronics faceplate
2100NV
Inlet valve assembly
2100BV
Bypass/needle valve assembly
2100RG
Regulator assembly
2100FM
Flow meter assembly
2100RT
Restrictor tube assembly
2100RBA
Reagent bottle adapter assembly with diffusion tube assembly
2100PA
Air pump assembly
2100AF
Air filter assembly
2100DV
Diverter valve assembly
2100VC
Check valve
2100TG
Tygon tubing (4ft)
2100FK115
Fuse kit assembly 115V
2100FK230
Fuse kit assembly 230V
210OK
O-ring kit - includes O-rings for reagent bottle and diffusion tube assembly