Thermo Scientific ITQ™ Series GC-Ion Trap MS


The Thermo Scientific ITQ™ Series represents the latest innovation in GC-ion trap mass spectrometry, building on our legacy of ion trap excellence. The new ITQ 700™, ITQ 900™ and ITQ 1100™ ion trap systems exemplify our commitment to providing instruments and GC/MS platforms ideal for applications from research to routine, and everything in between.

   Product Detail


From a small-footprint entry-level QA/QC instrument to a fully-featured, research-grade system with advanced MSn functionality, the Thermo Scientific ITQ Series offers a broad range of standard features along with an impressive list of options all designed to meet your lab's needs. Plus, as those needs change, the ITQ Series offers upgrade options to expand instrument capabilities and add flexibility and versatility to your analysis. The ITQ Series is supported by Productivity Solutions and workflow-oriented software packages. The ITQ Series features the ability to upgrade and add options to match the system to your lab's needs.

  • The Thermo Scientific ITQ 700™ GC/MS system offers the best value in routine GC/MS analysis, with best in class full scan ion trap sensitivity.
  • The Thermo Scientific ITQ 900™ expands the capabilities of the ITQ 700 with increased mass range and the added versatility of the TRACE GC Ultra.
  • The Thermo Scientific ITQ 1100™ is the ultimate system for the R&D laboratory, with extended mass range and powerful new MSn scan functions standard.

NEW Advanced MSn Scan Functions Power the ITQ Series

The ITQ Series features new MSn scan functions designed to improve performance and enhance the ease of use of the system. These new features are standard on the ITQ 1100 system, and are included with the MSn option for the ITQ 700 and the ITQ 900 systems.

Automated Collision Energy (ACE): Patent-pending ACE is a new function designed to greatly simplify the use of MS/MS by making optimization of collision energy automatic. Now the power of MSn is easier and more routine. ACE automatically calculates an estimated optimal collision energy based on product ion m/z and damping gas flow rtes. ACE then runs at three energies across each scan - the optimal plus one lower and one higher energy. ACE covers all of the bases every time you run MSn. Plus, any changes to precursor ion or damping gas flows are automatically considered, eliminating the need to re-optimize your method every time a change is made.

  • Three collision energies in each scan ensures optimal precursor ion fragmentation and product ion production
  • Easily apply the power of MSn for routine use
  • Offers a simplified starting point for manual methods

Pulsed Q Dissociation Mode (PQD):  PQD was originally developed for use on Thermo Scientific liquid chromatography-linear ion trap mass spectrometers. For the first time, this patented technique is now available for the ITQ Series. PQD is used during MSn experiments to improve the overall spectral quality, particularly in the low mass range. This allows you to see low m/z fragments that are usually excluded from standard collision induced dissociation (CID) spectra.

  • Generate information-rich mass spectral data, even in the low mass range
  • Eliminates low-mass cutoff
  • Produces precise, reproducible fragmentation

ITQ Series Highlights

  • External Ionization Ion Source: Standard on all ITQ systems, with independently-controlled heating from 125 to 300 oC for stable operation and superior chromatographic integrity. Plus, spectral integrity is enhanced when ionization takes place external to the trap, and the system stays cleaner longer, for improved uptime and longer periods between cleaning.
  • Quadrupole Ion Trap Mass Analyzer:  Unit mass resolution throughout the mass range, with durable inert materials for long life. Patented automatic gain control ensures that the ion trap is always filled with the optimum number of ions.
  • Detection System:  Digital electronic noise discrimination enhances sensitivity, and a post acceleration + 10 kV conversion dynode offers efficient positive and negative ion detection.

ITQ Series Options and Upgrades

  • MSn with ACE and PQD: Standard on the ITQ 1100, MSn with ACE and PQD is a powerful option for both ITQ 700 and ITQ 900. Routinely test for compounds in matrix that cannot typically be detected with other GC/MS techniques.
  • Direct Sample Probe: Directly analyze solids or liquids without chromatographic separation and without moving the GC by using the Direct Sample Probe. This option is available for all systems.
  • Vacuum Probe Interlock: Restore system performance, change from EI to CI, or use the direct sample probe, all without venting the instrument using the Vacuum Probe Interlock. The VPI is standard on the ITQ 1100 and is an option for the ITQ 700 and ITQ 900
  • Chemical Ionization: Use chemical ionization for added selectivity and sensitivity. Both positive and negative chemical ionization modes are supported, and digital reagent gas flow control ensures method stability and reproducibility. CI is available as an option for the ITQ Series.
Related Products

 Product#  Product Name Image  
         
 IQLAAAGAAHFACHMAFW   FOCUS GC 
  SELECT  
 IQLAAAGAAHFAFUMAMR   TRACE GC Ultra™ 
  SELECT  
 IQLAAAGAAIFAINMAQQ   Thermo Scientific ITQ 1100™ GC/MSn 
  SELECT  
 IQLAAAGAAIFAINMAQO   Thermo Scientific ITQ 700™ GC/MS 
  SELECT  
 IQLAAAGAAIFAINMAQP   Thermo Scientific ITQ 900™ GC/MS 
  SELECT  
 
Purchase Details
SKU : IQLAAAGAAIFAINMZZZ 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Literature Request
Postal Mail:
  • AI 3000/AS 3000 Autosampler Brochure
  • TriPlus Autosampler Brochure Request
  • Electronic Mail:
  • TriPlus Autosampler Product Specification
  • Direct Sample Probe Product Specification
  • Specifications:
    Source Type :External Ionization, Solid Inert
    EI Full Scan Installation Specification :100:1 RMS S/N using 1 pg OFN at m/z 272
    Vacuum System Options :70 L/s and 250 L/s turbomolecular pumps
    Negative Chemical Ionization Installation Spec :1000:1 RMS S/N using 1 pg DFBZ at m/z 362 (methane)
    Postive Chemical Ionization Installation Spec :100:1 RMS S/N using 100 pg of DFBZ at m/z 363 (methane)
    Gas Chromatograph Systems :FOCUS GC - single channel, SSL or TRACE GC Ultra - three channels, two injection ports