AutoGAGE

  AutoGAGE



AutoGAGE uses reed switch technologoy, which once installed never requires calibration. It measures temperature and level of two different fluid densities accurately and the accuracy is maintained over the entire length of the sensor.
   Product Detail


  • True digital electronics with precise increments   
  • Once installed, sensor never requires calibration   
  • Passive switching elements to reduce energy consumption   
  • All electronics sealed inside the sensor tube   
  • Intrinsically safe apparatus when connected to approved barriers   
  •  Approved remote intrinsically safe barriers available to mount within the RTU   

      enclosure 

  • Field wire connection includes a surge-protected plugable fuse board 

  • Submarine-type waterproof connection prevents moisture entry

  • One Float is standard, two Floats are optional for water interface 

  • Heavy wall outer tubing assures mechanical integrity over extended length 

  • Patent approved, number pending

  •  
    Purchase Details
    SKU : PID-14206 
    Request Quote
    Product Contact
     Sales Contact
      Service Contact
     
    Specifications:
    Measurement Length :Rigid tubing completely assembled: 2' to 25' in 1' increments. - Modular tubing assembled by installer: 5' to 80' in 1' increments.
    Tubing Material :Fiberglass: Standard - Stainless Steel or Teflon: Optional
    Float :UHMW-NYTROPHYL or NYTROPHYL Stainless Steel - One Standard, Two Optional for water interface. - Pass through a 4" tank port: Standard - Pass through a 3" tank port: Optional
    Measurement. Increments.& Accuracy :Standard 1/4" ? 1/8" 1/2" ? 1/4" - Optional 1/10" ? 1/20" 1/8" ? 1/16" - Other options available upon request
    Operational Temperature Range : (Digital) -40 Deg. F to +185 Deg. F: Standard - -40 Deg. F to +203 Deg. F: Optional
    Temperature Measurement :Display of EF: Standard - First Sensor 12" from bottom: Standard - 0-8 Temperature Sensors available with desired spacing - Display of Centigrade: Optional
    Temperature Measurement Accuracy :? .5 Deg. C: Standard - ? .1 Deg. C: Optional
    Input Power :12 VDC ? 15% at Sensor terminals
    Current Draw :70mA Maximum
    Working Pressure :15 psi: Standard - 15 to 1000 psi: Optional
    Communication :RS485 2 or 4 wire Baud rate and parity programmable - 4-20 mA signal available when connected to Digital to Analog Converter Board
    Wiring Requirements :2 Wire Communication: 2 Twisted Pair (16-18 AWG) Recommended - 4 Wire Communication: 3 Twisted Pair (16-18 AWG) Recommended