Model 42C Trace Level NO-NO2-NOX Analyzer

  Model 42C Trace Level NO-NO2-NOX Analyzer



Using Chemiluminescence, the 42C series is capable of measuring oxides of nitrogen from sub parts per billion (ppb) to 5,000 parts per million (ppm).  Extended troubleshooting diagnostics provide instantaneous indication of instrument operating status.  Reliable. Industry standard.  U.S. EPA Designated Method RFNA-1289-074 

This product is no longer offered.

   Product Detail


For High Sensitivity Air Monitoring

The Model 42C Trace Level represents the state-of-the-art subambient chemiluminescence measurement. Due to a combination of hardware design, plumbing arrangement, and software development, the Model 42C Trace Level can achieve detection limits of 50 ppt or better without sacrificing fast response, ease-of-operation, or cost effectiveness.

The Model 42C Trace Level utilizes a single reaction chamber and photomultipier tube which are time-multiplexed for NO, NOX, and zero measurement.  The difference between the three measurements allows the generation of three continuous signals of NO, NO2, and NOX.  Since the Model 42C Trace Level measures zero continuously, there is virtually no zero drift.

In the NOy configuration, the Model 42C Trace Level is modified to allow more accurate monitoring of total reactive oxides of nitrogen, for example nitric acid (HNO3) and peroxyacetyl nitrate (PAN). A molybdenum converter is used upstream of its normal location in order to minimize any NOy loses.

 
Related Products
 Product# Product Name Image  
  42CHL   Model 42C High Level Analyzer - See Model 42i HL
  Select  
  42C   Model 42C NO-NO2-NOX Analyzer - See Model 42i
  Select  
 
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Ranges :0-5, 10, 20, 50, 100, and 200 ppb
Linearity :+/- 1% of full scale
Zero Noise :25 ppt RMS (120 sec avg time)
Lower Detectable Limit (LDL) :50 ppt (120 sec avg time)
Zero Drift (24 hour) :Negligible
Span Drift (24 hour) :+/- 1% of full scale
Response Time (0 - 95%) (Automatic Mode) :60 sec (10 sec avg time); 90 sec (60 sec avg time); 300 sec (300 sec avg time)
Sample Flow Rate :1 LPM
Interferences :propylene rejection ratio > 20,000:1 ethylene rejection ratio>40,000:1
Operating Temperature :20-30°C
Power Requirements :90-100 VAC, 105-125 VAC, 210-250 VAC, 100 watts
Size and Weight :16.75" (W) x 8.62" (H) x 23" (D), 60 lbs
Output :voltage, current, RS-232/485