Personal DataRAM Series

  Personal DataRAM Series



Personal Dataram (pdr) measures airborne particulates concentration in real time, storing this information in detail for subsequent retrieval/printout/graphing through a computer. Range: 0.001 to 400 mg/m3. Palm-sized, the Personal Dataram weighs only 1/2 kilogram (18 oz.). Power options include replaceable 9V alkaline battery which provides up to 20 hours of operation, AC line power, or optional 72 hour rechargeable battery pack.
   Product Detail


Model Numbers pDR 1500 and pDR-1000AN

  • pDR 1500 is an active, real-time, personal aerosol monitor/ data logger, with aerodynamic sizing.
  • pDR-1000AN is the passive sampling version (requires no vacuum pump)

    Applications:
  • Indoor air quality monitoring
  • Walk-Through surveys
  • Personal exposure monitoring
  • Time and motion studies
  • Workplace and plant monitoring
  • Remediation site worker surveillance
  • Remote alarming
  • Mobile monitoring in vehicles and aircraft
  • Unattended long-term monitoring

Key Features and Benefits:

Measures Airborne Particulates Concentration in Real Time
With conventional air quality monitoring methods, you won't find out until tomorrow that you have reached dangerous levels or are out of compliance today.  In contrast, the personal DataRAMTM alerts you to a problem within seconds and allows you to take immediate corrective action.  It stores this information in detail for subsequent retrieval / printout / graphing via a computer.

The world's smallest and most versatile direct reading personal aerosol monitor, the personalDataRAM measures mass concentrations of dust, smoke, mists, and fumes in real-time, and sounds an on-board audible alarm whenever a user-defined level is exceeded.  Integral large-capacity data logging capability permits storage of 13,000 data points in up to 99 discrete tags.  Any tag can store up to 13,000 averages plus tag maximum and STEL values.  When you begin a run, the instrument automatically tags and time stamps the data collected.

Highest Performance of Any Real-Time Personal Particulate Monitor
With a measurement range from 0.001 to 400 mg/m3 (auto-ranging), an optically feedback-stabilized sensing system, ultra-low power consumption, and rigid all-metal construction, the personalDataRAM sets new standards for sensitivity, long-term stability, and reliability.  These capabilities allow its use in many applications where such compact monitors were previously considered unsuited.

Easy to Read Two-Line Display
The personalDataRAM's two-line LCD readout continuously displays both real-time and time averaged (TWA) concentration values, updated every second.  Other screens are easily selected by scrolling through a simple user-friendly menu.  Self-diagnostics continually monitor the unit's operation and flag any problems.  LCD screens indicate remaining memory, battery status, optical background level, as well as any electronic malfunctions may also be selected.

Only four tactile-feedback keys (including On-Off) are required to perform all operations and commands, such as enable / disable logging and alarms, review of program parameters, and review of maximum / STEL data.

Extremely Compact and Rugged Design
Palm-sized, the pDR-1000AN weighs only 1/2 kilogram (18 ounces).  The unit can be attached to a belt or shoulder strap, hand-held, operated on a table top, or mounted on a tripod.

The personalDataRAM's rugged, yet attractive, brushed aluminum case is designed to protect the unit's optics and electronics in even the harshest industrial environments.  Heavy-duty molded bumpers shield the monitor from inadvertent mishandling and moderate impact.  The absence of any moving parts (e.g., pumps, motors, valves, etc.) and the use of low-power semiconductor components throughout ensures long life and failure-free operation.

Sensing Principle Achieves High Correlation with Gravimetric Measurements
The personalDataRAM is a light-scattering photometer (i.e., nephelometer) that incorporates a pulsed, high output, near-infrared light emitting diode source, a silicon detector / hybrid preamplifier, collimating optics, and a source reference feedback PIN silicon detector.  The intensity of the light scattered over the forward angle of 45o to 90o by the airborne particles passing through the sensing chamber is linearly proportional to their concentration.

The personalDataRAM's optical configuration produces optimal volume response to particles in the size range of 0.1 to 10µm, achieving high correlation with standard gravimetric measurements of the respirable and thoracic fractions.

Passive Air Sampling is Silent and Reliable
The personalDataRAM's passive air sampling technique has been thoroughly field-proven since 1980.  Air surrounding the monitor circulates freely through the open sensing chamber by natural convection, diffusion, and background air motion.  With this passive nephelometer sampling method, concentration measurements do not depend on the air velocity through the sensing chamber.

Easy Programming and Downloading with a Computer
The personalDataRAM is easily programmed from any IBM-compatible personal computer.  Using the pDR-COM software provided with the unit, operating parameters such as logging period, display averaging time, alarm level, and mode can be modified.  With logging enabled, the unit automatically tags and time stamps the data collected, then stores the data for subsequent retrieval / printout / graphing.  The personalDataRAM retains the setup information until the next.

Using the pDR-COM software, logged data can be downloaded to a PC for direct tabular and graphic display, and/or printout.  The data can be imported into most common spreadsheet programs by following the instructions provided.

Simple Zeroing and Calibration
Each personalDataRAM comes gravimetrically calibrated (NIST-traceable) in mg/m3 using standard SAE fine (ISO fine) test dust.  Zeroing with particle free air is accomplished quickly and effectively under field conditions using the zeroing kit (included).  Special firmware controls an automatic calibration check referenced to the optical background set at the factory.  Gravimetric field calibration can be performed by comparison with a filter sampler and by programming of the calibration constant.

Three Power Options
The personalDataRAM can be powered by:

  • A replaceable 9V alkaline "transistor" battery that provides up to 20 hours of operation
  • AC line power and a universal voltage power supply (included) for long-term, continuous monitoring
  • Optional rechargeable, sealed nickel-metal-hydride battery pack that attaches rigidly to the personalDataRAM's base, providing up to 72 hours of operation between charges

For maximum flexibility, power sources can be changed even while operating the unit.

Maintenance, Service, and Factory Support
The personalDataRAM has no moving parts to wear out.  Only the 9V battery needs to be replaced.  Instructions for simple and easy periodic cleaning of the sensing chamber are provided.  Routine factory check-out and calibration are recommended on a two-year cycle.

Our experienced technical/applications support team can provide expert advice and practical solutions to aerosol-related problems.  This invaluable resource is available to customers for the life of our instruments, many of which have been in field use for more than a quarter of a century.

Standard Accessories
Each personalDataRAM comes with several accessories:

  • Universal voltage power supply/charger
  • Digital communications cable
  • pDR-COM software disk
  • Zeroing kit
  • Belt clip kit
  • Instruction manual
  • Carrying case

Optional accessories are:

  • Rechargeable (NiMH) battery pack
  • Active sampling adapter kit
  • Shoulder strap
  • Remote alarm unit
  • Multiple set carrying case
 Personal DataRAM Series
 Product# Price  Image  Product Description  
         
 pDR-1200      -  
 
 
 personal DataRAM monitor for active sampling & aerodynamic sizing. Includes carrying case, digital communications cable, zeroing kit, belt clip kit, AC power supply, analog signal output cable and cyclone   SELECT  
 pDR-1000AN      -  
 
 
 personal DataRAM hand-held monitor, includes soft shell carrying case, digital communications cable, Z-Pouch zeroing kit, belt clip kit, AC power supply, analog signal output cable and PC Software application with operator manual   SELECT  
Purchase Details
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Accuracy :+/-5% of reading +/- precision
Particle Size Range of Maximum Response :0.1 to 10 um
Resolution :0.1% of reading or 0.001 mg/m3, whichever is larger
Concentration Display Updating Interval :1 second
Concentration Measurement Ranges (auto ranging) :0.001 to 400 mg/m3
Alarm Level Adjustment Range (user selectable) :Selectable over entire measurement range
Alarm Averaging Time (user selectable) :Real-Time (1-60 seconds) or STEL (15 minutes)
Data Logging Averaging Periods (user selectable) :1 second to 4 hours
Logged Data (each data point) :Average concentration, time/date and data point number
Logged Data (run summary) :Overall average and maximum concentrations, time/date of maximum, total number of logged points, start time/date, total elapsed time (run duration), STEL concentration and time/date of occurance, averaging (logging) period, calibration factor, and tag number
Total Number of Data Points in Memory :13,000
Number of Data Tags :99
Elapsed Time Readout Range :0 to 100 hours (resets to 0 after 100 hours)
Time Keeping and Data Retention :Greater than 10 years
Readout Display :LCD 16 characters (4 mm height) x 2 lines
Serial Interface :RS232, 4,800 baud
Computer Requirements :PC compatible, 486 or higher; Windows 95 or higher
Weight :18 ounces (0.5 kg) pDR-1000AN; 24 ounces (0.68 kg) pDR-1200
Power :Internal battery: 9V alkaline, 20 hours run time (typical); AC source: universal voltage adapter (included) 100-250 volts, 50-60Hz (CE marked); Optional battery pack: rechargeable NiMH 72 hour run time (typical)
Operating Environment :-10 to 50 degrees C (14 to 122 degrees F); 10 to 95% RH, non-condensing
Storage Environment :-20 to +70 degrees C (-4 to +158 degrees F)
Dimensions :153 mm (6.0 in) H x 92 mm (3.6 in) W x 63 mm (2.5 in) D pDR-1000AN; 160 mm (6.3 in) H x 205 mm (8.1 in) W x 60 mm (2.4in) pDR-1200
Flow Rate Range :1 to 10 liters/minute pDR-1200 ONLY
Particle Sizing :1.0 to 10 um pDR-1200 ONLY