Infrared Analyzer, MIRAN SapphIRe


Use of infrared spectroscopy provides the MIRAN SapphIRe Analyzers with the unique ability to specifically and accurately measure many gases with a single unit.
   Product Detail


MIRAN SapphIRe DL (Replaces SapphIRe 1 & 5)

MIRAN SapphIRe SL (Replaces SapphIRe 30 & 30E)

MIRAN SapphIRe XL (Replaces SapphIRe 100 & 100E)

The MIRAN SapphIRe Series of Ambient Air Analyzers is the most versatile gas detection system on the market today.

The Analyzer's wavelength generator has a unique design that allows accurate and fast wavelength selection.  This feature alone separates the MIRAN SapphIRe Analyzer from other gas analyzers.

The MIRAN SapphIRe Analyzer is available in three models with gas calibrations from one to over 100 gases.  Any model can be easily upgraded to another model in the series, allowing you to economically meet both current requirements and future increased needs.

The MIRAN SapphIRe has the ability to identify unknown airborne compounds using the ThermoMatch software option.  Designed with the needs of the industrial hygienist and emergency response community in mind, the analyzer can be brought to the incident resulting in quiker corrective action and less money expended on "blank" samples being analyzed at a lab.

All applications need to be examined and approved before an order will be accepted via the Completion of an Applications Feasibility Request.

Features
  • Easy to use
  • Selective
  • Sensitive for sub-ppm detection
  • Versatile and easily  upgraded
  • Lightweight and portable

Applications
Industrial Hygiene
Real-time detection of vapors in job environments promotes safe work habits.  MIRAN SapphIRe analyzers monitor at typical government-regulated levels.

Emergency Response Analysis
The MIRAN SapphIRe assists emergency response personnel in qualifying hazardous spills and emissions.

Indoor Air Quality Studies
The MIRAN SapphIRe makes precise spot measurements for compounds such as CO2, CO, formaldehyde, or organic vapors.

Waste Anesthetic Gases
Service technicians can identify leaks on anesthetic delivery systems by using the MIRAN SapphIRe Ambient Air Analyzer as a part of Preventative Maintenance (PM) work.
Fume Hood/Tracer Gas Analysis



Leak Detection for process maintenance
Using a leak detection probe, you can set up the MIRAN SapphIRe to check for leaks around many types of process equipment.

 


MIRAN SapphIRe XL

The MIRAN SapphIRe XL.  Offers optimal measurement capabilities for high-end users who need to measure a wide variety or mixed atmosphere of gases.  

  • Contains over 120 single gas applications with customization capability                         
  • Ideal for consultants, industrial hygienists, regulatory agencies, research scientists, and emergency response professionals

MIRAN SapphIRe SL

The MIRAN SapphIRe SL Provides flexibility for users who perform similar measurements on a routine basis.  

  • Contains over 50 single gas applications with customization capability.                         
  • Popular with indoor air quality specialists and anesthetic gas monitoring technicians

MIRAN SapphIRe DL

The MIRAN SapphIRe DL is designed for users who regularly encounter a limited number of air monitoring applications.

  • Features quick and easy operation for enforcement agencies and specified compound measurement projects.

Training and Support

Need technical assistance?  Our experienced team of laboratory specialists is available to help you determine the right system for your application.   And...we back it up with the technical support you need.

A list of compounds is now available


Warranty Registration Form

Please complete this warranty registration form.  The information will assist Thermo Scientific to provide better service and register your company as the recipient of the warranty.

Click here for Warranty Form

MIRAN is a registered trademark of Thermo Fisher Scientific.


 

 
Purchase Details
SKU : Infrared Analyzer, MIRAN SapphIRe 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Specifications:
Detector Type :Single beam infrared spectrophotometer
Optics :Linear Variable Filter (LVF) from 7.7 to 14.1; Seven Fixed Band Pass Filters 1.8, 3.3, 3.6, 4.0, 4.2, 4.5, and 4.7
Pump Flow Rate :After power up: 20 seconds minimum; threee minutes maximum
Alarms :User Definable
Readout :8 line x 40 character LCD
Response Time :18 seconds to 90% of final reading
Pathlength :0.5 m to 12.5 m
Sample Cell Volume :2.23 liters
Battery :Internal, rechargeable NiCd. 7.2V nominal; 5.7 Ah Capacity. Discharge time 4 hours; Recharge time 4 to 6 hours
Output : 0-1Vdc, Parallel, Serial
Output :0-1Vdc, Parallel, Serial
Dimensions :21.8" (W) x 14.4" (H) x 7.6" (D); 553mm (W) x 365mm (H) x 193mm (D)
Mass :24 lbs (10 kg)
Intrinsic Safety :User specified models are certified for CENELEC, Groups IIC, Zone 1 and 2
Certifications :ETL (Class I, Div 1, Groups B, C, & D, Temperature Class T4; ETL-C (Class I, Div. 1, Groups, B, C, & D, Temperature Class T4); CENELEC (EEx ib d IIB + H2 T4)