Welcome Guest from United States
Sign In Change Country
  0 Items
Search:
Explosion Proof Gas Detection, FX-SMT Transmitters
Gas: Part Number: Range: Calibration Kit: Replacement Sensor: Replacement Smart Sensor:
Ammonia (NH3) 67-0024-09 0 - 100 ppm in 1 ppm increments 81-6412-05 65-2431-07 65-2432-07
Arsine (AsH3) 67-0024-13 0 - 1.00 ppm in 0.01 ppm increments 81-6412-06 65-2431-08 65-2432-11
Carbon Monoxide (CO) 67-0024-01 0 - 500 ppm in 1 ppm increments 81-6413-09 65-2425-01 65-2432-14
Chlorine (Cl2) 67-0024-04 0 - 10.0 ppm in 0.1 ppm increments 81-6412-02 65-2431-01 65-2432-01
Chlorine Dioxide (ClO2) 67-0024-16 0 - 2.00 ppm in 0.01 ppm increments See Note 1 65-2431-11 65-2432-13
Combustibles 67-0021-01 0-100% LEL 81-6413-XX 61-0101 N/A
Diborane (B2H6) 67-0024-18 0 - 1.00 ppm in 0.01 ppm increments 81-6412-06 65-2431-08 65-2432-18

Fluorine (F2)

67-0024-07 0 - 10.0 ppm in 0.1 ppm increments 81-6412-02 65-2431-01 65-2432-01
Hydrogen Chloride (HCl) 67-0024-05 0 - 30.0 ppm in 0.1 ppm increments 81-6412-03 65-2431-04 65-2432-04
Hydrogen Cyanide (HCN) 67-0024-08 0 - 50.0 ppm in 0.1 ppm increments 81-6412-04 65-2431-02 65-2432-02
Hydrogen Fluoride (HF) 67-0024-06 0 - 10.0 ppm in 0.1 ppm increments 81-6412-02 65-2431-05 65-2432-05
Hydrogen Sulfide (H2S) 67-0024-02 0 - 100 ppm in 1 ppm increments 81-6412-01 65-2425-02 65-2432-15
Nitric Oxide (NO) 67-0024-14 0 - 100 ppm in 1 ppm increments 81-6412-07 65-2431-03 65-2432-03
Nitrogen Dioxide (NO2) 67-0024-15 0 - 20.0 ppm in 0.1 ppm increments 81-6412-08 65-2431-10 65-2432-12
Oxygen (O2) 67-0024-03 0 - 30.0 % Vol. in 0.1% Vol 81-6413-08 65-1061 65-2432-16
Ozone (O3) 67-0024-12 0 - 1.00 ppm in 0.01 ppm increments See Note 2 65-2431-09 65-2432-10
Phosphine (PH3) 67-0024-10 0 - 1.00 ppm in 0.01 ppm increments 81-6412-06 65-2431-08 65-2432-08
Silane (SiH4) 67-0024-11 0 - 20.0 ppm in 0.1 ppm increments 81-6412-11 65-2431-08 65-2432-09
Sulfur Dioxide (SO2) 67-0024-17 0 - 20.0 ppm in 0.1 ppm increments 81-6412-09 65-2420-02 65-2432-17




Note 1: For ClO2 calibration, Thermo Scientific uses an Advanced Calibration Designs, Inc. Model 300 (Phone: +1 520.290.2855)

Note 2: For O3 calibration, use the Model 165 (Phone: +1 508.520.0430)

>> Back to Explosion Proof Gas Detection, FX-SMT Transmitters product page.